Specifications – Triplett 9305 User Manual
Page 5
4
Specifications
Function
Range
&
Resolution
Accuracy (% of reading)
AC Current
(50/60Hz)
40.00AAC
± (2.5 % + 8 digits)
400.0 AAC
± (2.8 % + 8 digits)
DC Voltage
400.0 mVDC
± (0.8% + 2 digits)
4.000 VDC
± (1.5% + 2digits)
40.00 VDC
400.0 VDC
600.0 VDC
± (2 % + 2 digits)
AC Voltage
(50-400Hz)
4.000 VAC
± (1.8% + 8 digits)
40.00 VAC
400.0 VAC
600.0 VAC
± (2.5% + 8 digits)
Resistance
400.0 Ω
± (1.0% + 4 digits)
4.000KΩ
± (1.5% + 2 digits)
40.00KΩ
400.0KΩ
4.000MΩ
± (2.5% + 3 digits)
40.00MΩ
± (3.5% + 5 digits)
Capacitance
40.00nF
± (4.0% reading + 20 digits)
400.0nF
± (3% reading + 5 digits)
4.000μF
40.00μF
100.0μF
± (4.0% reading + 10 digits)
Frequency
Sensitivity:15Vrms
10-10kHz
± (1.5% reading + 2 digits)
Temp
(type-K)
(probe accuracy not
included)
-20.0 to
760.0
°C
± (3%rdg+5°C)
-4.0
to1400.0
°F
± (3%rdg+9°F)