Pass, Fail, Cable test examples – Triplett Low Voltage Pro User Manual
Page 20: Open, Split, Good cable open on pair 1-2, Split pairs (pairs 1,2 and 3,6 split)

GOOD CABLE
OPEN on PAIR 1-2
1
2
3
6
4
5
7
8
PIN#
PIN#
1 Orange/White
2 Orange
3 Green/White
6 Green
4 Blue
5 Blue/White
7 Brown/White
8 Brown
PIN#
1
2
3
6
4
5
7
8
PIN#
1 Orange/White
2 Orange
3 Green/White
6 Green
4 Blue
5 Blue/White
7 Brown/White
8 Brown
EIA/TIA 568B
STRAIGHT THRU CABLE
(MOST POPULAR)
PASS
12345678
S
12345678
S
FAIL
OPEN
CABLE
TEST
The Cable Testing Pack is standard on all LVPro Models.
These following are examples of the TIA 568 test that the
LVPro performs on Category cable. In addition to PASS/FAIL
and wiremap that is shown here, there are also timing tests
(delay, skew) and impedance measurement (ohms). Models
with the Length-
RLQ
Pack APP (Models 2 and 3) add Length
and the RLQ quality.
CABLE TESTING PACK (ALL MODELS)
1
2
3
6
4
5
7
8
1
2
3
6
4
5
7
8
Orange/White
Orange
Green/White
Green
Blue
Blue/White
Brown/White
Brown
PIN#
PIN#
SPLIT PAIRS
(PAIRS 1,2 AND 3,6 SPLIT)
SPLIT
FAIL
123
45
6
78
S
18