Resistance, Range, Open circuit voltage: less than 3v on all ranges – Triplett 1101a User Manual
Page 11: Temperature, Overload protection: 500vrms, Diode test and continuity beeper, Transistor hfe test

Resistance
Range Resolution
Accuracy
200Ω 0.1Ω
± (0.8% rdg + 5 digits)
2000Ω
1Ω
20KΩ 10Ω
200KΩ 100Ω
± (0.8% rdg + 2 digits)
20MΩ 10KΩ
± (1.0% rdg + 5 digits)
Open Circuit Voltage: Less than 3V on all ranges
Overload Protection: All ranges 500Vrms (AC or DC Current).
Temperature
Range Resolution Accuracy
-40°F to 302°F
± (1.0% rdg + 5 digits)
303°F to 1832°F
1 degree Fahrenheit
± (1.5% rdg + 15 digits)
Overload Protection: 500Vrms
Thermocouple:
K-Type
Note:
The provided thermocouple is only intended to measure
Temperatures up to 300 degrees F. Exceeding this
temperature may damage the probe.
Diode Test and Continuity Beeper
Displays relative
reading in mV,
not actual diode voltage
Test current about 1mA.
Open circuit voltage about 2.8V
Beeper sounds if
meter displays <70.
(Approx. 30Ω)
Test current about 1mA.
Open circuit voltage about 2.8V
Transistor hFE test
hFE
Can measure NPN or PNP
transistor hFE. Range: 0-1000 ß
Base current about
10µA,Vce about 2.8V
11