beautypg.com

Resistance, Range, Open circuit voltage: less than 3v on all ranges – Triplett 1101a User Manual

Page 11: Temperature, Overload protection: 500vrms, Diode test and continuity beeper, Transistor hfe test

background image

Resistance

Range Resolution

Accuracy

200Ω 0.1Ω

± (0.8% rdg + 5 digits)

2000Ω

1Ω

20KΩ 10Ω

200KΩ 100Ω

± (0.8% rdg + 2 digits)

20MΩ 10KΩ

± (1.0% rdg + 5 digits)

Open Circuit Voltage: Less than 3V on all ranges

Overload Protection: All ranges 500Vrms (AC or DC Current).

Temperature

Range Resolution Accuracy

-40°F to 302°F

± (1.0% rdg + 5 digits)

303°F to 1832°F

1 degree Fahrenheit

± (1.5% rdg + 15 digits)

Overload Protection: 500Vrms

Thermocouple:

K-Type

Note:

The provided thermocouple is only intended to measure

Temperatures up to 300 degrees F. Exceeding this
temperature may damage the probe.

Diode Test and Continuity Beeper

Displays relative

reading in mV,

not actual diode voltage

Test current about 1mA.

Open circuit voltage about 2.8V

Beeper sounds if

meter displays <70.

(Approx. 30Ω)

Test current about 1mA.

Open circuit voltage about 2.8V

Transistor hFE test

hFE

Can measure NPN or PNP

transistor hFE. Range: 0-1000 ß

Base current about

10µA,Vce about 2.8V




11