background image

15

Model 301 Tube Squaring Machine

92-0630 Rev. 130308

NOTE:

CAUTION:

NOTE:

NOTE:

NOTE:

INSTALLING A COLLET IN THE MODEL 301QL

Remove the Ball Lock Pin from the Collet Clamping Assy of the Model 301QL by

pulling straight out.

Be sure that the Toggle Clamp Lever is in the up position to allow the pin to

be pulled out.

Swing the Clamping Head Assy upward to allow the Collet to be slid into place.

Insert the Collet into the tapered Collet Clamping Model 301QL.

Swing the Collet Clamping Assy down into position.

Insert the Ball Lock Pin completely into the hole provided for it in the Collet clamping

Assy.

Be sure that the Toggle Clamp Lever is in the up position in order to permit

the pin to be pushed into the Collet Clamping Assy.

Insert the pipe or tube to be machined into the Collet.

Verify a clearance of 1/16” (1.6 mm) between the Tool Bits(s) and the pipe or tube

face as held by the Collet.

As the Collet closes, the tube is drawn toward the Tool bit.

Do not let the Tool Bit touch the pipe or tube at this time.

To do so will cause damage to the Tool Bit or the Tube Squaring Machine when

power is applied.

Lock the tube or pipe in position by pushing the Toggle Clamp Lever all of the way

down.

Attach the power supply to the Model 301 and pull the Trigger to start rotation of the

Cutting Head

POWER REQUIREMENTS

Power requirements for a Model 301 equipped with an Air Motor.

The air supply should be 22 cfm at 90 psi (10 L/s at 621 kPa).