Thermo Technologies SMT 400 User Manual
Page 24
![background image](https://www.manualsdir.com/files/807585/content/doc024.png)
23
SECTION 5 SPECIFICATIONS
ELECTRICAL:
Supply Voltage:
220-240V AC Single Phase
Fuses:
1 X 6.3A Slow Blow, 1 X 1A Quick Blow.
Relay Outputs:
Pump 1 Relay:
2A single pole - output live
when energized (max. 400W).
Pump 3 Relay:
2A single pole - output live
when energized (max. 400W).
Pump 3 Relay:
2A single pole - output live
when energized (max. 400W).
A1 Relay:
2A changeover 3 pin isolated (volt free
contacts) can be used for mains voltage
only.
(max. 400W).
A2 Relay:
2A single pole - output live
when energized (max. 400W).
The Total Output Current must not exceed 5.5A
MECHANICAL:
Dimensions:
width: 165mm
height: 100mm
depth: 85mm
weight: SMT 400 0.92Kg
Sensor: (each) 0.1Kg
Box Material:
Plastic (ABS)
Front Panel:
Reverse printed
Display:
Large LCD supertwist graphics
SENSORS:
Type:
Platinum PT100
Wire:
3- wire compensated
Cable Length:
1 X Collector sensor 25m
1 X Tank sensor 5m
1 X Return sensor 5m
Battery:
9V PP3 Rechargeable
PARTS LIST
SMT 400 Control Unit
C0128
Collector Sensor Pocket (TC)
A0477
25m Collector Sensor (TC) A0741
Return Sensor Pocket (TR)
A0683
10m Collector Sensor (TC) A7143
Tank Sensor Pocket (TT)
A0332
0.5m Return Sensor (TR)
A0740
Sensor Extender 10m
A6911
5m Return Sensor (TR)
A7141
Sensor Extender 20m
A6921
5m Tank 1 Sensor (TT1)
A0742
Sensor Extender 50m
A6951
0.25m Tank 2 Sensor (TT2) A7140