beautypg.com

Thermo Technologies SMT 400 User Manual

Page 11

background image

10

3.4

SET SCREEN 1 - MAIN SYSTEM PARAMETERS

1

30 90 60

90

2

4

TC

TT1

TT2

TM

TF

T

1

1

2

2

3

***

6

T

S

1

Set Screen function selector
Pressing this key once reveals Set Screen 1. The main system parameters
are set using this screen.

2

TC is the minimum collector temperature which will activate the pumps
(recommended set value: 30

o

C).

3

TT1 is the State 1 to State 2 divert temperature; (In normal/default operation
this is the Tank1 to Tank2 divert temperature). The default value is set to
90°C for a one pump system. In an application that has more than one
pump, this value must be adjusted to the required divert temperature, (i.e. a
temperature of 40°C is recommended).

4

TT2

In the default state (as shipped from the factory), the Tank 2
sensor input is disabled. This is denoted by an X in the TT2
window. If your system has two tank 2 sensors, then you will
need to follow step (a) as follows:

2

3

4

6

5

7

8

9

1