MOUNTING

The LD-60 detector can be mounted in any
position. The more usual insertion points are
shown in the drawing.

In positions 1 the LD-60 acts as a maximum
level detector. In positions 2 the LD-60 acts as
a minimum level detector and in position 3 it
acts as an empty pipe detector (for example,
to protect a pump).

If the LD-60 is installed in a horizontal position
it is recommended to install it with the tines
vertical to avoid accumulation of substances,
especially in the case of high viscosity
materials.

To indicate the position of the tines the LD-60
has a round mark on two of the flats of the nut.
These marks should be in a vertical position
when the detector is installed in a horizontal
position.

In the same way, when the detector is installed where there is flow, the position must be taken
into account. The flat part of the tines must be aligned parallel with the flow direction.

If the viscosity is high, the tines must be kept away from other objects (such as the wall of the
tank). In these cases it is preferable to install a longer detector.