beautypg.com

Tecfluid LD60 User Manual

Page 2

background image

2

WORKING PRINCIPLE

The LD-60 level switch is based on the variation of the natural resonant frequency of a vibrating
fork, when it comes into contact with a liquid or solid

This variation is detected by the internal electronics and is used to determine the state of the
output .

TECHNICAL DATA

Material:

Fork: EN 1.4404 (AISI 316L). Others on demand.


Housing:

Polycarbonate.


Pipe fittings:

Threads G1 (BSP), 1 NPT.


Models:

24-250 Vac. Maximum load 350 mA. 2 wire connection with series
load


12 - 55 Vdc. Maximum load 350 mA. 3 wire connection


Switching time:

> 1s


Hysteresis:

± 2 mm with H

2

O


Working Limits:

Viscosity. Up to 10.000 cSt

Density. > 0,6 kg / l

Process temperature (product). -30 a 120ºC

Ambient temperature. -20 a 70ºC

Standard pressure: PN 16

Ingress Protection:

IP65

Conforms with the Directives 73/23/CE & 89/336/CE

Conforms with the Pressure Equipment Directive 97/23/CE

This equipment is considered as being a pressure accessory and NOT a safety
accessory as defined in the 97/23/CE directive, Article 1, paragraph 2.1.3.

!