beautypg.com

Other functions & settings, Headphone monitor functions, Referencing to an external clock source – Teac RC-601MKII User Manual

Page 25: Failsafe function, Connecting audio signals, Monitoring on headphones

background image

TASCAM RC-601MKII

25

OTHER FUNCTIONS & SETTINGS

Headphone Monitor Functions

On the RC-601MKII, you can input stereo audio output
signals (max. 4 systems) from external equipment, and
monitor these signals using the headphone connected to the
PHONES terminal.

Connecting Audio Signals

Stereo audio signals of up to four systems can be input to
the MONITOR IN terminal on the rear panel.

Connect to the audio output (max. output level: +6 dBV,
unbalance) of the external equipment according the
following pin arrangement.

[NOTE]

• The

MONITOR IN terminal must be connected to also

when the audio output signal of the CD-601MKII that is
connected to the RC-601MKII is to be monitored.

MONITOR IN Pin Arrangement

Pin No. Signal Name

1

Lch IN1

Monitor input 1 Lch

2

Rch IN1

Monitor input 1 Rch

3

N.C.

4

Lch IN2

Monitor input 2 Lch

5

Rch IN2

Monitor input 2 Rch

6

N.C.

7

Lch IN3

Monitor input 3 Lch

8

Rch IN3

Monitor input 3 Rch

9

N.C.

10

Lch IN4

Monitor input 4 Lch

11

Rch IN4

Monitor input 4 Rch

12

N.C.

13

N.C.

14

Lch GND1

Monitor input 1 Lch shielded

15

Rch GND1

Monitor input 1 Rch shielded

16

N.C.

17

Lch GND2

Monitor input 2 Lch shielded

18

Rch GND2

Monitor input 2 Rch shielded

19

N.C.

20

Lch GND3

Monitor input 3 Lch shielded

21

Rch GND3

Monitor input 3 Rch shielded

22

N.C.

23

Lch GND4

Monitor input 4 Lch shielded

24

Rch GND4

Monitor input 4 Rch shielded

25

N.C.

Monitoring on Headphones

Select the headphone monitor source using the MONITOR
SELECT
knob. The selected source signal is output from
the PHONES terminal.

Adjust the monitor level using the LEVEL knob.

Referencing to an External Clock

Source

The remote control unit can be operated referenced to an
external digital clock.

1 Connect the word clock from an external source to

the WORD SYNC IN terminal on the rear panel of the
CD-601MKII.

2 Set menu No. 04 (“CLOCK”) to “EXT”.

EXT CLK” and the sampling frequency (“44.1k” or “48k”)
are lit on the clock display area of the display area.

The default setting is “INT” (referenced to internal clock).

Failsafe Function

The failsafe function is a safety function for preventing
playback from discontinuation when an operation key is
touched inadvertently during a final take.

In the default setting, the failsafe function is ON, and
operation of keys other than STOP, PLAY MODE and
DISPLAY MODE is not accepted during online playback.
Also, in the online READY mode, operation of search-
related keys such as the TRACK key and numeric keys and
the MENU key is not accepted.

[NOTE]

• Even when the failsafe function is ON, entry by the

numeric keys is accepted in the direct cue point locate
mode and flash start mode.

When the failsafe function is set to OFF at menu item No.
10 (“F_SAFE”), all keys (excluding SEARCH dial, FLASH
READY
key and MEMO key in the online playback mode)
are functional.

The failsafe function ON/OFF setting is valid on both the
CD-601MKII and the RC-601MKII.

1

14

13

25

RC-601MKII_Eng.indd 25

3/24/2005 2:38:23 PM