b. Installing the Lift in the Ceiling
1. Raise the Lift into the ceiling and line up the four (4) mounting holes
in the Lift's top frame with the 1/2” threaded rods of the supporting
structure. Make sure that there is a top nut and a flat washer on each
threaded rod before the Lift is mounted. See Figure 6. (Plenum
Shrouds & Decorative Cover require additional hardware installed on
the threaded rods before the Lift.)
2. Once the Lift's top frame has been inserted, add a hexnut to each
threaded rod below the Lift frame. Always leave the top nut loose to
allow adjustments until the Lift is leveled.
3. Level the Lift's top frame side-to-side and front-to-back using the
lower hexnuts on the threaded rods.
4. Once the Lift is leveled, secure the Lift to the threaded rods by
tightening the upper hexnuts. Do not over tighten the fasteners as it could distort the Lifts top frame.
5. If the Power Sensor is used, please refer to the Power Sensor Instructions, otherwise, plug the 12-pin
connector of the Wall Plate Controller into the 12-pin socket on the Lift's gray electrical box mounted on
the Lifts top frame. The Wall Plate Controller includes 75-feet of cable and is shipped with the Lift. It is
located in the cardboard box attached to the lid of the Lift's shipping crate.
6. Once the Lift is properly installed in the ceiling and leveled, you can remove the shipping blocks.
Remove the blocks by removing the screws and tie-raps holding them in place.
TO AVOID CABLE SPILLS
•
Do not push the lift bottom frame upwards once the Lift has been installed.
•
Make sure that there are no obstructions in the Lifts path. If the bottom frame is lowered onto an
obstruction the cable will slack and spill over the cable drum. If the cable spills over the cable
drum and the Lift is not stopped the cable will back-wind onto the cable drum causing severe
damage to the Lift and accessories.
8. ELECTRICAL CONNECTIONS
Electrical connections should be made at this time. The SVS Mini 7EX Lift requires 110V/60Hz at 2.3 Amps
and is supplied with a six foot power cord. The SVS Mini 7EX Lift is controlled with a 24VAC Low Voltage
Controller called the Wall Plate Controller. This controller can easily be connected to external controllers like
Crestron, AMX, Extron, etc. The Wall Plate Controller is supplied with 75-feet of cable (22 AWG, 9 conductor).
Wall Plate Controller Information
Wire Color
Connector Pin Function
Brown
3
Down to Show Position when 24VAC connected from Pin 1
Green
4
Down to Service Position when 24VAC connected from Pin 1
Red
2
Up when 24VAC connected from Pin 1
White
1
24 VAC Out (Common) (can be measured between Pin 1 and Pin 7)
Black
7
Power LED Return (Ground)
Orange
8
Power LED+
1. Make sure that the area below the Lift is clear and that all cable are clear of the Lift.
2. Apply power to the Lift by plugging it into an AC Outlet.
SVS Mini 7EX Lift Installation Instructions
Page 9 of 17
Figure 6. Lift Mounting
Hardware