beautypg.com

Confi guration—restore factory defaults – Studio Technologies 76 V.1.04 User Manual

Page 26

background image

Issue 4, September 2008

Model 76/77 User Guide

Page 26

Studio Technologies, Inc.

for Surround

Press and hold both the Surround/Stereo and Dim buttons for 5 seconds
to restore Model 77 factory defaults. Once defaults have been restored,
the associated LEDs will light. After the buttons are released, confi gura-
tion mode will be exited and normal operation will resume.

Confi guration—Restore Factory Defaults

Factory Defaults: Device

address

A1.

Stereo output can be enabled.

–20.0 dBFS digital input reference level.

+4.0 dBu monitor output nominal level.

Reference level is set for fully attenuated (minimum) monitor output level.

Attenuation display mode selected.

85.0 dB SPL reference level.

Auto reference level off disabled.

–20.0 dB dim level.

Remote mute all disabled.

Remote dim disabled.

LFE downmix disabled.

6.0 dB channel pop solo up offset level.

–6.0 dB channel pop solo down offset level.

Warning:

Each Model 77 unit must have a unique address. Restoring factory defaults will reset only this

specifi c Model 77 to device address A1. If another connected unit is already confi gured for

address A1, normal system operation will stop.

Note:

The 5-second delay is a safety feature ensuring that the factory defaults will not be accidently

restored.