Configuration, Confi guration, Confi gurable parameters – Studio Technologies 76 V.1.04 User Manual
Page 13: Entering and exiting the confi guration mode

Model 76/77 User Guide
Issue 4, September 2008
Studio Technologies, Inc.
Page 13
for Surround
carton as well as each “solo” Model 77. 
These cables implement all nine connector 
pins in a one-to-one manner.
When connecting one or two Model 77 
units to a Model 76 all nine pins of the 
interconnecting cables can be connected 
in parallel (“multed”). This will connect the 
data signals between the units and route 
the Model 76’s 12 volt DC power source to 
both Model 77 units. A basic cable imple-
mentation would have pin 1 (data+), pin 6 
(data–), pin 4 (DC+), and pin 9 (DC–) 
connected. Connecting to a third and 
fourth Model 77 requires that only pin 1 
(data+) and pin 6 (data–) be connected 
from the Model 76 to the third and fourth 
Model 77 units. (This will connect the “data 
bus” from the Model 76 to all the Model 
77 Control Consoles.) An external 12 volt 
DC source must provide power to the third 
and fourth Model 77. This power source, 
capable of supplying a minimum of 200 
milliamperes of current (100 milliamperes 
per Model 77), needs to connect to pin 4 
(DC+) and pin 9 (DC–) on the third and 
fourth unit.
Previous paragraphs of this user guide 
discussed the Model 76 to Model 77 cable 
length issues. Please review that informa-
tion prior to creating the interconnection 
scheme to be used for installing multiple 
Model 77 units.
Confi guration
After the physical installation has been 
completed it’s important that the system’s 
confi guration options be carefully reviewed. 
In most cases one or more of the operating 
parameters will need to be revised to meet 
the needs of a specifi c installation. Many 
of the parameters will impact the signal 
fl ow in to and out of the Model 76 Central 
Controller. Other parameters affect how the 
one or more Model 77 Control Consoles 
will display status conditions and respond 
to user commands.
Confi gurable Parameters
Many StudioComm functions can be 
confi gured to meet the exact needs of an 
installation. The Model 77 Control Console 
is used to display and select the desired 
system confi guration. Here’s an overview 
of what can be confi gured:
• Model 77 Device Address
• Stereo
Output
• Digital Input Reference Level
• Monitor Output Nominal Level
• Reference
Level
• Overall Display Mode
• Reference Level in dB SPL
• Auto Reference Level Off
• Dim
Level
• Remote
Inputs
• LFE
Downmix
• Channel Pop Solo Mode Offset Levels
The confi guration diagrams, located at the 
end of this section, give details on set-
ting each parameter. An overview of each 
confi gurable parameter is provided in the 
following paragraphs.
Entering and Exiting the 
Confi guration Mode
A small button is located on the back of 
each Model 77 Control Console, adjacent 
to the 9-pin D-sub connector. Pressing and 
holding this button for two seconds places 
