Overall display mode, Reference level in db spl – Studio Technologies 76 V.1.04 User Manual
Page 16

Issue 4, September 2008
Model 76/77 User Guide
Page 16
Studio Technologies, Inc.
for Surround
5. Being careful not to disturb the posi-
tion of the rotary level control, enter 
the confi guration mode by pressing 
and holding the confi guration button 
located on the Model 77’s back panel.
6. Once the confi guration mode has been
entered, the monitor outputs will mute. 
Press and hold the reference button; 
its associated LED will begin to fl ash. 
After fi ve seconds the LED will light 
steadily to indicate that a “snapshot” 
of the new reference level has been 
taken. The Model 77’s numeric display 
will then show the value of the new 
reference level. The value shown will 
always be a negative number as it’s 
always a value less than the maximum 
output level. The reference level button 
can now be released.
7. To complete the process the confi gura-
tion mode must be exited. This is per-
formed by again pressing and holding 
the confi gure button for two seconds. 
The new reference level is now stored 
in the Model 76’s nonvolatile memory. 
Only by repeating the entire procedure 
can the value be changed.
Once the confi guration mode has been 
exited, the monitor outputs will again be-
come active. Confi rm that the correct level 
has been stored by pressing the reference 
level button. The SPL meter should display 
the desired level. If not, repeat the calibra-
tion procedure to achieve the desired goal.
You might wonder why you have to press 
and hold the reference level button for fi ve 
seconds before the selected value is 
recognized. This is provided specifi cally 
so that unauthorized users won’t acciden-
tally change the reference level while they 
experiment with the confi guration mode. 
Only if you know the “secret” will you be 
able to store a new value.
Overall Display Mode
The Model 77’s 4-digit numeric display can 
be confi gured to display the output level 
in either an attenuation mode or an SPL 
mode. In the attenuation mode the output 
level is shown as a reduction in value rela-
tive to the maximum output level. When the 
rotary control is used to set the output level 
to its maximum the display will show 0.0. 
As the rotary control is moved in the coun-
terclockwise direction the display will show 
negative values, reaching approximately 
–69.5 dB before the full mute function au-
tomatically mutes the outputs.
In the SPL mode the display can be confi g-
ured to allow the output level to be present-
ed to users in terms of the actual sound 
pressure level (SPL). Used in conjunction 
with the reference level in dB SPL confi gu-
ration and the stored reference level, SPL 
mode allows a user to see a visual repre-
sentation of the SPL level that is present 
in the listening environment. While it takes 
a little more care to correctly implement 
the SPL display mode, it can offer an en-
hanced experience for StudioComm users.
Reference Level in dB SPL
The reference level in dB SPL confi gura-
tion allows a specifi c SPL value to be asso-
ciated with the stored reference level value. 
In this way whenever the monitor output is 
at the reference level, either through acti-
vating the reference level function or manu-
ally adjusting the rotary level control, the 
Model 77’s display will show the confi gured 
SPL level. Whenever the monitor output is 