Space Ray PTS Series Single Stage User Manual

Page 55

background image

Form 43343330

-54-

Aug 2012

38a

22a

38

31

1

44

5

21

3

45

3

20

2

35, 62

36

30

29

3

5, 5a

7

26

26a

25 24

1

22c

22b

14

1a

1a

22d

15

18

6

46

41, 41a

40

27

43

40a

3

17a

7

9a

Draft Inducer

Motor

Gas Valve

Air Switch

Transformer
Primary 120V

Secondary 24V

High Voltage Cable

Electrode
Gap 1/8”

CONTINUE TO

ADDITIONAL

HEATERS

Terminal Block

CONNECTION WIRING DIAGRAM

If any of the original wire as supplied with the
appliance must be replaced. It must be
replaced with wiring material having a
temperature rating of at least 105oC. (18
AWG. - UL / CSA 600V Type TEW)

When connecting the supply circuit to the
heater, wiring material having a minimum size
of 14 AWG and a temperature rating of at
least 90oC shall be used.

Schéma de circuit de connexion

Vers les autres

radiateurs

Plaque à

bornes

Transformateur

bobine primaire 120ÊV

bobine secondaire 24ÊV

pressostat

Robinet à gaz

Écartement

d'électrode

3,2Êmm

Haute tension

Bloc d'allumage

Moteur

d'amorce

d'aspiration

GND

V2

V1

(W)TH

Ignition Module (Fenwal)

(R) 24VAC

L1

IND

NC

P.SW

HV

S1

Flame Sensor

FACTORY WIRING

FIELD WIRING

Circuit d'origine

Connexions client

L2 NEUTRAL

L1 (hot) 120V

THERMOST

A

T

(line volt

age)

GROUND

MONITORING LIGHTS
Lampes témoins

42874020 6/07

Red
Light

Amber
Light

L1 Black

L2 Black
(ribbed)

Black

White

Black
(ribbed)

Black

Green

Green

Violet

Red

Blue

Green

Violet

Black

Y

ellow

Red

Orange

Orange

Fuse 2A

Fusible

Optional Low
Voltage (24V)
Thermostat
Remove jumper wire.

Blue

Blue

(jumper)

Terminal
Block

TISS
(Tube Integrity

Safety Switch)
Remove jumper wire.

Blue

Blue

(jumper)

Terminal Block

Plaque à

bornes

Blue

SCHEMATIC WIRING DIAGRAM

42785020 03/08

120V

GND

V2

V1

(W)TH

24V

AC

L1

IND

NC

P

.SW

HV

S1

MV MV

Motor

Transformer

24V

Igniter

Flame
Sensor

Ignition Module

Air
Switch

Thermostat

TISS

Red
Light

Gas
Valve

Amber
Light

7

23

3

22

52

61

16,16a 17

18

18

19

15

23

33

32

48

48, 48a, 48b

47

12

8, 28

13

9

11

8, 11a

10

22a

34

31

38a

WARNING: Improper

installation, adjustment,
alteration, service or
maintenance can cause
property damage, injury
or death. Read the
Installation, Operating
and Maintenance
Instruction thoroughly
before servicing this
equipment.

AVERTISSEMENT: Une

installation, un réglage, une
modification, une réparation
ou un entretien incorrect peut
entraîner des dommages
matérials, des blessures ou
la mort. Lisez attentivement
les instructions d’installation,
de fonctionnement et
d’entretien avant de procéder
à l’installation ou à l’entretien
de cet équipment.

WARNING: If not

installed, operated and
maintained in accordance
with the manufacturer’s
instructions, this product
could expose you to
substances in fuel or from
fuel combustion which can
cause death or serious
illness and which are
known to the State of
California to cause cancer,
birth defects or other
reproductive harm.

WARNING: This product

contains a chemical known
to the state of California to
cause cancer.

This heater can be
installed in various
configurations as shown
in the heater layout
section of the instructions

42875000 Rev. E 10/04

END VIEW

RECOMMENDED GAS CONNECTION POSITIONS WITH 24” FLEXIBLE GAS HOSE

A

B

A

B

Position 1

Position 2

Gas pipe work must
not restrict opening of
hinged service doors.

Alternate Positions

150mm

SIDE VIEW

C

Burner Movement

Flexible
Connector

12”
(305mm)

Sediment Trap
(Drip Leg)

Optional Second Stage Regulator with
Vent Leak Limiter if required to reduce
the Supply Pressure below 14” W.C.

7 5/8”

194mm

Note: When venting a single
heater horizontally through a
combustible outside wall the
vent must pass through a 2”
clearance thimble (Air Jet No.
4VT or Ameri-vent No 4EWT
or other thimbles which are
listed by nationally recognized
testing agency.

Attach a vent cap (Breidert No.
4L or equivalent)

Minimum equivalent length of
vent pipe = 5ft (1.5m)
Maximum equivalent length of
vent pipe = 50ft (15m)

Nota: le conduit d'échappement

d'un radiateur simple traversant

un mur combustible doit passer

dans une gaine de 2 po (Air Jet

n° 4VT ou Ameri-vent n° 4EWT

ou autre gaine normalisée par

un organisme d'essai reconnu

à l'échelle nationale.

Poser un capuchon d'évent

(Breidert n° 4L ou équivalent)

Longueur minimale équivalente

du tuyau d'échappement = 1,5m

(5pi)

Longueur maximale équivalente

du tuyau d'échappement = 15m

(50pi)

THIS UNIT EQUIPPED WITH A
2 AMP IN LINE-FUSE FOR
OVERCURRENT PROTECTION
OF CONTROL CIRCUIT

ELECTRIC SHOCK

HAZARD

Disconnect electrical supply
before servicing
Failure to follow these
instructions may result in
death, serious injury or
property damage.

WARNING

42922030 Rev - 11/07

SIDEWALL VENTING ONLY

UN MUR LATÉRAL A É R AT I O N

22d

63

57

55

54

58

59

49

59

60

51

56

65

66

67

68

2-Stage Thermostat

43269060 rev A

HI
C

LO

3b, 21a

4, 6

6

GAS TYPE

SUPPLY PRESSURE
Pression de Sortie

Type de Gaz

MAXIMUM

MINIMUM

MANIFOLD PRESSURE
Pression a l’echappement

INPUT Btu/Hr

Consommation Btu / Hr

ORIFICE SIZE

Dimensions bec Veilleuse

MODEL NO.
No. de Modelè

Installation in:
1. Aircraft hangers must be in accordance with the standard for Aircraft Hangers.
ANSI/NFPA 409 (latest edition).
2. Public garages must be in accordance with the standard for parking structures,
ANSI/NFPA 88a (latest edition), or with the standard for repair garages,
ANSI/NFPA 88b (latest edition)

SERIAL NO.
No. de Série

LIGHTING & SHUTDOWN INSTRUCTIONS
1. Turn on gas & electrical supply.
2. Set thermostat to call for heat.
3. Ignition should occur after prepurge.
4. If ignition fails, the unit will spark for approximately 21 seconds

& go into safety lockout. Turn thermostat (or power) off for 60
seconds to take out of lockout.

5. If heater does not light, shut off gas completely for 5 minutes

before attempting to relight.

6. To shut down the heater, turn off the gas & electrical supply.

Infrared Radiant Tube Heater

Radiateur à tuve rayonnant à infrarouge

Gas Fired products Inc. Charlotte, NC

INSTRUCTIONS D’ALLUMAGE ET DE FERMETURE
1. mettre la valve a gaz et l’interrupteur a “ON”.
2. Creer une demande de chauffage au thermostat.
3. L’allumage devrait se produire apres de prepurge.
4. Si l’allumage ne se fait pas, le controle d’allumage continu de

produire des etincelles sur une periode de 21 sec. et ensuite
tomber en securite. Mettre le thermostat (ou le courant) en
position d’arret (OFF) pour une periode de 60 sec. a fin
d’interrompre le processus de securite.

5. Si l’appareil ne s’allume pas, fermez le gaz completement pour

une period de 5 min. avant d’effectuer une nouvelle tentative
d’allumage.

6. Pour fermer l’appareil, fermez le gaz et le courant electrique.

For indoor installation only

Installer à l’intérieur seulement
Vented or Unvented

ELECTRICAL:

ALTITUDE

ANSI Z83.20b / CSA 2.34b - 2003

Tel: 1800 438 4936 e-mail [email protected]

CODE DATE

42848000 Rev. H 10/04

MAX ANGLE:

Max Angle

Electrique

Combustible material must be located outside the clearance dimensions listed.

Ceiling Clearance is 18” (46cm) when installed in an UNVENTED configuration. Ceiling
clearance is 18” (46cm) when the optional U-bend reflectors are not used.

Failure to do so may result in death, serious injury or property damage

Models: PC(S,A)

43344080 10/07

Le dégagement au-dessus de l'appareil doit être d'au moins 46 cm quand l'appareil est installé

SANS ÉCHAPPEMENT.

Le dégagement au-dessus de l'appareil doit être d'au moins 46cm

quand les réflecteurs d'angle optionnels ne sont pas utilisés.

D

D

Model No

A

B

C

D

E

F

75

27”

60”

30”

48”

12”

(69cm)

(15cm)

(152cm)

(76cm)

(122cm)

(30cm)

100

66”

88”

40”

66”

20”

(168cm)

(15cm)

(224cm)

(102cm)

(168cm)

(51cm)

125

66”

101”

40”

66”

20”

(168cm)

(15cm)

(257cm)

(102cm)

(168cm)

(51cm)

150

84”

106”

48”

84”

24”

(213cm

(15cm)

(269cm)

(122cm)

(213cm)

(61cm)

Horizontal

B

C

A

A

45 degrees

B

C

E

F

Montage horizontal

Montage à 45°

43344110 03/08

Install the gas flexible hose as shown in the diagram below:
Sharp bends, kinks, twists and tension in the hose may cause failure resulting in a gas leak.
Failure to follow these instructions may result in death, serious injury or property damage.

Position

“A”

“B”

“C”

1

6 3/4” (171mm) 9 5/8” (245mm)

3 7/8” (99mm)

2

9 1/8” (232mm) 7 5/8” (194mm)

3 7/8” (99mm)

11”

TUBE INTEGRITY SAFETY SYSTEM

43269020 Rev. B 03/08

In the event of tube failure the wire inside
the sleeve will break. For safety replace
the entire wire assembly including the
sleeve PN 44176010

Patent Pending

The system must be installed with tension
on the spring.

FRAGILE! DO NOT Lift the burner box by
these wires.

Reflector edge.

BURNER SUSPENSION CHAIN
MUST BE USED TO SUPPORT
BURNER BOX. FAILURE TO USE
EYEBOLT SUSPENSION WILL VOID
MANUFACTURER’S WARRANTY.

USE A TURNBUCKLE FOR LEVEL
ADJUSTMENT OF BURNER BOX.

43269030 12/07

ATTENTION INSTALLER!

THE GAS CONTROL VALVE IS FACTORY
SET AT “OFF” POSITION. OPEN THIS
ACCESS PANEL TO TURN THE GAS
VALVE TO “ON” POSITION. BY THIS
ACTION YOU CERTIFY THAT ALL GAS
CONNECTIONS AND CHECKS COMPLY
WITH WRITTEN I & O INSTRUCTIONS
SHIPPED WITH THIS HEATER.

43269040 12/07

43269040 12/07

43269040 12/07

43269050 Rev. A 03/08

DANGER

Failure to do so may result in death,
serious injury or property damage

FIRE HAZARD

This access panel must be closed
tightly with all the necessary screws
during operation.

Never operate the heater with the
access panel open or removed.

43269050 Rev. A 03/08

DANGER

Failure to do so may result in death,
serious injury or property damage

FIRE HAZARD

This access panel must be closed
tightly with all the necessary screws
during operation.

Never operate the heater with the
access panel open or removed.

This manual is related to the following products: