beautypg.com

0) venting – Space Ray PTS Series Single Stage User Manual

Page 37

background image

Form 43343330

-36-

Aug 2012

D.

D.

D.

D.

LOW VOLTAGE (24V) THERMOSTAT CONNECTIONS

LOW VOLTAGE (24V) THERMOSTAT CONNECTIONS

LOW VOLTAGE (24V) THERMOSTAT CONNECTIONS

LOW VOLTAGE (24V) THERMOSTAT CONNECTIONS –

– MULTIPLE HEATERS (utilizing a fan center

MULTIPLE HEATERS (utilizing a fan center

MULTIPLE HEATERS (utilizing a fan center

MULTIPLE HEATERS (utilizing a fan center

relay)

relay)

relay)

relay)

Burner Control Box

Ground

N Neutral

L1 Hot (120V)

Low voltage
thermostat (24V)

Continue To
Additional
Heaters

Power Supply
Cord (120V)

Receptacle

TH

C

Jumper factory
installed for optional
24V thermostat

Fused
Disconnect
switch

24V

coil

C

R

G

NO

TH

C

Fan Center Relay Part No. 30169000
Contact Rating: 120V, 40VA, 12A
(maximum of 6 heaters per relay)

16.0)

VENTING

Failure to do so may result in death, serious injury, property damage or illness
from Carbon Monoxide poisoning.

Heaters installed in an unvented mode require a minimum ventilation flow of
4 CFM per 1,000 Btu/hr of total installed capacity.

In buildings with airborne contamination the heater must be installed with
fresh air for combustion.

CARBON MONOXIDE HAZARD

A.

A.

A.

A.

BASIC FLUE VENTING

BASIC FLUE VENTING

BASIC FLUE VENTING

BASIC FLUE VENTING — Venting must comply with the latest edition of the National Fuel Gas Code (ANSI
Z223.1-latest edition) or the authority having jurisdiction. Other venting references are in the equipment
volume of the ASHRAE Handbook.

Mode

Mode

Mode

Modellll

Heat

Heat

Heat

Heat

exchanger

exchanger

exchanger

exchanger

length ft

length ft

length ft

length ft

Maximum vent length ft.

Maximum vent length ft.

Maximum vent length ft.

Maximum vent length ft.

(4” diameter)

(4” diameter)

(4” diameter)

(4” diameter)

Maximum Fresh air

Maximum Fresh air

Maximum Fresh air

Maximum Fresh air

intake length ft (4”

intake length ft (4”

intake length ft (4”

intake length ft (4”

diameter)

diameter)

diameter)

diameter)

Max. combination of

Max. combination of

Max. combination of

Max. combination of

fre

fre

fre

fresh air and vent ft.

sh air and vent ft.

sh air and vent ft.

sh air and vent ft.

(4” diameter)

(4” diameter)

(4” diameter)

(4” diameter)

PTS/U 40

10

45

50

75

PTS/U 40

20

45

50

75

PTS/U 50

20

45

50

75

PTS/U 50

30

35

40

65

PTS/U 50

40

25

30

55

PTS/U 75

20

45

50

75

PTS/U 75

30

35

40

65

PTS/U 75

40

25

30

55

PTS/U 100

30

45

50

75

PTS/U 100

40

35

40

65

PTS/U 100

50

25

30

55

PTS/U 125

30

60

50

75

PTS/U 125

40

50

40

65

PTS/U 125

50

40

30

55

PTS/U 125

60

30

20

45

PTS/U 150

40

60

50

75

PTS/U 150

50

50

40

65

PTS/U 150

60

40

30

55

PTS/U 175

50

60

50

75

PTS/U 175

60

50

40

65

This manual is related to the following products: