23.2)

REMOVING GAS VALVE AND MANIFOLD ASSEMBLY

Step 1

Remove side
access panel.

Loosen screws from
manifold clamp and
burner assembly.

Step 3

Open hinged access
panel and disconnect
wires from gas valve.

Step 4

Remove (6) screws from
end panel. Rotate gas valve
and manifold assembly
slightly counter-clockwise
and slide out from housing.

Step 2

23.3)

AIR SWITCH PRESSURE CHECK

P1
+

P2
-

P1
+

P2
-

0.65” WC

+

-

Connector
Tees

Air
Switch

Digital or Inclined
Water Manometer
scale 0-2”w.c.

Temporary 1/4” ID Silicone /
plastic tubing for pressure
test.

Common “C”

Normally
open “NO”

Red Wire

Orange Wire
& Black Wire