Wiring, E h e h – SOMFY Sonesse Ultra 50 User Manual
Page 5
EN
5
Copyright © 2014 Somfy SAS. All rights reserved.
Images not contractually binding
2.2. Wiring
Cables which pass through a metal wall must be protected and isolated using a sheath
or sleeve.
Attach cables to prevent any contact with moving parts.
The cable on the Sonesse 50 can be removed. If it is damaged, replace it with an identical
cable.
Leave the drive power supply cable accessible: it must be possible to replace it easily.
-
Switch off the power supply.
-
Connect the drive according to the information in the table below:
Neutral
(N)
Live
(L1)
Live
(L2)
Earth
( )
120V -60 Hz
White
Black
Red
Green
L1L2N
2.1.3. drive/tube assembly
1) Slide the drive into the roller tube.
For roller tubes which are smooth inside, position the notch
previously cut on the boss on the crown.
2) The drive wheel must be locked in place to prevent it
moving along the roller tube:
• This can be done either by fixing the roller tube to the
drive wheel using 4 x Ø 5 mm self-tapping screws,
or by using 4 x Ø 4.8 mm steel pop rivets placed 5
mm to 15 mm from the outer rim of the drive wheel,
regardless of the roller tube.
The screws or pop rivets must only be attached to the
drive wheel and not to the drive.
3) Slide the end cap into the roller tube.
2.1.4. installing the drive/tube assembly
The motorised product must not be compressed between the brackets
1) Install and fix the drive/tube assembly onto the end
bracket
f and onto the drive bracket g:
Ensure that the drive/tube assembly is secured onto
the end bracket. This operation prevents the drive/
tube assembly from coming out of the end bracket
mounting when the roller blind reaches the lower end
limit position.
2) Depending on the type of bracket, fit the stop ring
h in
place.
1)
2)
h
g
a
b
Ø>47mm
e h
e
h
f
a
b
Ø>47mm
e h
e
h
15 mm
5 mm
20 mm
L1
1)
2)
3)