Rj9 rj45, Data wiring, 1) data cable rj9/rj45 – SOMFY Sonesse Ultra 50 RS485 User Manual
Page 6: 1) with power out, 2) without power out
6
EN
Copyright © 2014 Somfy SAS. All rights reserved.
1) Data cable RJ9/RJ45.
1: + RS485
2: - RS485
3: Power out *
4: GND
1
2
3
4
5
6
7
8
4
3
2
1
1
2
3
4
5
6
7
8
4
3
2
1
1: + RS485
5: Not used
2: - RS485
6: Not used
3: Not used
7: Not used
4: Power out *
8: GND
RJ9
RJ45
1: + RS485
2: - RS485
3: Not used
4: GND
1
2
3
4
5
6
7
8
4
3
2
1
1
2
3
4
5
6
7
8
4
3
2
1
1: + RS485
5: Not used
2: - RS485
6: Not used
3: Not used
7: Not used
4: Not used
8: GND
1.1) With Power out
.
1.2) Without Power out .
data wiring
Connect the data cable to the motor according to the information in the tables below.
Between the RS485 data wire and the RS485 product, the cable length should not exceed
20m.
Make sure the data cable is not pinched or damaged during the installation of the drive/
tube onto the end bracket.