beautypg.com

Seaward B255 User Manual

Page 34

background image

Operating Manual

Clare B255 Power Tool & Appliance Test Station

30

9.Electrical Specification

Earth Continuity Test:

Display Range:

0

Ω to Infinity (INF.)

Measured Range:

0 to 1

Ω

Accuracy:

+/-10% of the reading

Duration:

Unlimited

Recommended Duration:

up to 5 seconds with 2 minute intervals

Test Current:

up to 25A into 0.1

Ω

500V Flash Test:

Voltage:

500v AC, +/-10%

Trip Current:

5mA, 10mA

Duration:

Unlimited

Recommended Duration:

up to 5 seconds

1250V Flash Test:

Voltage:

1250V AC, +/-10%

Trip Current:

5mA, 10mA

Duration:

Unlimited

Recommended Duration:

up to 5 seconds

3000V Flash Test:

Voltage:

3000V AC, +/-10%

Trip Current:

5mA

Duration:

Unlimited

Recommended Duration:

up to 5 seconds

3750V Flash Test:

Voltage:

3750V AC, +/-10%

Trip Current:

5mA

Duration:

Unlimited

Recommended Duration:

up to 5 seconds

Load Test:

Display Range:

0 to 25A

Accuracy:

+/-5% full scale

Voltage:

230V or 110V, 50/60Hz

Test Current:

up to 15A @ 230V, up to 16A @ 110V

Duration:

Unlimited

Leakage Test:

Display Range:

0 to 5mA

Accuracy:

+/-5% full scale

Voltage:

230V or 110V, 50/60Hz

Duration:

Unlimited