Seaward B255 User Manual
Page 34

Operating Manual
Clare B255 Power Tool & Appliance Test Station
30
9.Electrical Specification
Earth Continuity Test:
Display Range:
0
Ω to Infinity (INF.)
Measured Range:
0 to 1
Ω
Accuracy:
+/-10% of the reading
Duration:
Unlimited
Recommended Duration:
up to 5 seconds with 2 minute intervals
Test Current:
up to 25A into 0.1
Ω
500V Flash Test:
Voltage:
500v AC, +/-10%
Trip Current:
5mA, 10mA
Duration:
Unlimited
Recommended Duration:
up to 5 seconds
1250V Flash Test:
Voltage:
1250V AC, +/-10%
Trip Current:
5mA, 10mA
Duration:
Unlimited
Recommended Duration:
up to 5 seconds
3000V Flash Test:
Voltage:
3000V AC, +/-10%
Trip Current:
5mA
Duration:
Unlimited
Recommended Duration:
up to 5 seconds
3750V Flash Test:
Voltage:
3750V AC, +/-10%
Trip Current:
5mA
Duration:
Unlimited
Recommended Duration:
up to 5 seconds
Load Test:
Display Range:
0 to 25A
Accuracy:
+/-5% full scale
Voltage:
230V or 110V, 50/60Hz
Test Current:
up to 15A @ 230V, up to 16A @ 110V
Duration:
Unlimited
Leakage Test:
Display Range:
0 to 5mA
Accuracy:
+/-5% full scale
Voltage:
230V or 110V, 50/60Hz
Duration:
Unlimited