beautypg.com

Technical characteristics, Sce170 – Scotsman SCE170 User Manual

Page 18

background image

Technical Characteristics

Typical Cycle Time

15 - 20 minutes (time depends upon how clean unit is, plus the air and water temperatures).

Typical Harvest Ice Weight

1.6 to 1.8 lb. ice harvested per cycle.

Typical Low Side Pressure

25 PSIG just before harvest

Typical Freeze Cycle Discharge Pressure

Air cooled: 300 PSIG declining to 210 PSIG

Water cooled: 245 PSIG

Refrigerant Type / Charge

Air Cooled: R-404A / 17 ounces A series, 16 ounces B and Cseries

Water Cooled: R-404A / 9 ounces A series, 11 ounces B series and 10 ounces C series

Harvest Time:

Varies with ambient, usually about 1.5 - 2 minutes. Unit is in harvest until the curtain opens. The
unit may remain in harvest a maximum of 7 minutes, after which the machine returns to the freeze
cycle.

Typical Low Side Pressure, in harvest

85 - 100 PSIG

Typical Discharge Pressure in harvest

195 - 210 PSIG

Hi Pressure Cut Out

Cuts Out at (450 PSIG air cooled, 350 PSIG water cooled); Cuts In at 350 PSIG (air cooled)

Typical Compressor Amp Draw

Freeze: 6-7

Harvest: 7-8

Superheat

4-6

o

F. 10 minutes into freeze cycle. TXV is not adjustable.

Finish Freeze Time

4 minutes after cube size thermostat closes (indicator light on control board is ON in Timed Freeze)

Air cooled fan motor

16 watt rating; 1500 RPM; CW. Stops during harvest.

Compressor

Copeland hermetic, capacitor start, induction run.

Water Pump Motor

4 pole, unit bearing type.

Cube Size Control

Adjustable Cut In temperature as needed to obtain correct ice bridge thickness, about 8

o

F. - 10

o

F.

Cut In at about 31 PSIG (with normal heat load)

SCE170

June 2002

Page 18