Electrical Connections:
Locate the nameplate for the current requirements,
and then determine the wire size and type per the
National Electric Code. The machine requires a
solid chassis to earth ground wire.
Refer to the wiring diagram. The ice
machine should be connected to it’s
own electrical circuit, and be
individually fused.
Voltage, when the unit is under full
load, must remain within the limitations
listed on page 2.
LOW VOLTAGE CAN CAUSE
EQUIPMENT MALFUNCTION
AND/OR DAMAGE
All external wiring should conform to
the National, State, and local electrical
codes. Usually the services of a
licensed electrician will be required.

DETAIL OF

JUNCTION BOX

JUNCTION

BOX

POWER SUPPLY

FM2400RH