Service Diagnosis

SYMPTOM

POSSIBLE CAUSE

PROBABLE FIX

No ice is made

No cooling due to low refrigerant
charge

Locate leak, recover remaining
refrigerant, replace dryer,
evacuate and weigh in nameplate
charge.

Will not harvest due to hot gas
valve not opening.

Check for voltage to coil in
harvest, if there is voltage check
coil, if coil is ok, replace hot gas
valve

No cooling due to compressor not
operating

Check compressor for voltage,
continuity, and operation.
Replace if found to be faulty.

Will not harvest due to not
enough harvest time.

Adjust harvest time longer.

Will not harvest due to lack of
water.

Check water supply & distribution
system. Clean water system with
Scotsman Ice Machine Cleaner.

Makes ice, but very little

High discharge pressure, due to
dirty condenser, faulty fan motor,
fan pressure switch, not enough
water thru water cooled
condenser.

Check for causes of high
discharge pressure and correct.

Inlet water temperatures and
room ambient very high

Advise user, suggest additional
room cooling.

Compressor inefficient

Check/replace compressor

Cubes are wrong size/shape

Cube size control not adjusted
properly

Adjust cube size control

Water system is restricted with
minerals

Clean water system with
Scotsman Ice Machine Cleaner

Not enough water

Check water supply pressure

Check water supply for restrictions

Ice fused together in bin

Ice in bin too long

Advise user to pour water on ice
to ease removal

Too many minerals in water

Suggest water treatment to user.

Water drips on ice

Water distributors loose

Set water distributors in place on
top of evaporator.

Some water is normal.

Advise user.

Cube size too small

Adjust thicker.

Water system is dirty

Clean water system with ice
machine cleaner.