beautypg.com

Cme250, Technical characteristics – Scotsman CME250 User Manual

Page 18

background image

Technical Characteristics

Typical Cycle Time

••

21 minutes @ 90

o

F. air and 70

o

F. water

••

16 minutes @ 70

o

F. air and 50

o

F. water

Typical Harvest Ice Weight

••

2.5 - 3 pounds.

Typical Low Side Pressure Just Before Harvest

••

Air cooled = 35 PSIG; Water cooled = 28 PSIG

Typical Freeze Cycle Air Cooled Discharge Pressure

••

220 PSIG @ 70

o

F. air and 50

o

F. water

••

280 PSIG @ 90

o

F. air and 70

o

F. water

Refrigerant Charge:

••

Air cooled = 27 ounces HP62

••

Water cooled = 17 ounces HP62

Harvest Time

••

Pre-set at 2 and a quarter minutes. Adjustable to match field requirements.

Typical Low Side Pressure, in harvest:

••

Water cooled = 86 PSIG ; Air cooled = 100 PSIG @ 90

o

F. air and 70

o

F. water

Typical Discharge pressure, in harvest:

••

Water cooled = 160 PSIG; Air cooled = 200 PSIG @ 90

o

F. air and 70

o

F. water

Hi Pressure Cut Out Point:

••

450 PSIG, air cooled; 400 PSIG, water cooled

Fan Pressure Switch

••

240 PSIG C.I.

••

190 PSIG C.O.

Hi Temperature Cut Out Point:

••

140

o

F. (at hot gas valve)

Typical Compressor Amp Draw:

••

10-13 during the freeze cycle and 11-14 during the harvest cycle.

Compressor:

••

Copeland: RS43C1E-CAA-213

Water Inlet Valve Flow Rate:

••

.33 g.p.m.

Cube Size Thermostat:

••

Adjustable Cut In as needed to obtain correct cube size, C.I. range between 24

o

F. and 0

o

F

Bin Thermostat

••

Adjustable; C.I. range between 38.5

o

F. and 43.5

o

F, C.O. range between 33.5

o

F. and 38.5

o

F

Thermostatic Expansion Valve

••

Not adjustable

CME250

October 1994

Page 18

This manual is related to the following products: