Harvest Cycle:

During the harvest cycle, the refrigerant flows from
the compressor, through the discharge line to a
branch in the line containing the Hot Gas Valve.
This valve is Open during the harvest cycle,
allowing the hot discharge gas to bypass the
condenser and enter the evaporator at its inlet.

The hot discharge gases warm up the evaporator
enough to allow the surface of the ice frozen to the
evaporator to melt. The remaining ice will then fall
off into the bin.

During the Harvest Cycle, the inlet water valve
opens, filling the reservoir and allowing the
reservoir to overflow the drain.

Inlet

Water

Valve

(OPEN)

Water
Pump

Evaporator

Water Distribution

System

Hot Gas Valve

(OPEN)

Suction Line

Liquid Line

Condenser

Dryer

Compressor

Discharge Line

Thermo. Exp.

Valve

Water Reservoir

Refrigeration Schematic

Hot Gas

Valve

Filter

Fan Motor

CME250