beautypg.com

For the electrician – Scotsman CME1202 User Manual

Page 7

background image

FOR THE ELECTRICIAN

SEE NAMEPLATE for current requirements to
determine wire size to be used for electrical
hookup. The cuber requires a solid chassis to
chassis earth ground wire. See Wiring Diagram.

Be certain the cuber is connected to its own
electrical circuit and individually fused. Voltage
variation should not exceed ten percent of the
nameplate rating, even under starting conditions.
Low voltages can cause erratic operation and
may be responsible for serious damage to the ice
maker.

FOLLOW ALL APPLICALBE CODES

Electrical connections are made at the rear of
the ice maker, inside the junction box.

All external wiring should conform to the
national, state and local electrical code
requirements. Usually an electrical permit and
services of a licensed electrician will be
required.

ELECTRICAL CONNECTIONS, WATER COOLED

ELECTRICAL CONNECTIONS, AIR COOLED

GROUND SCREW

DETAIL OF

JUNCTION BOX

JUNCTION

BOX

HAND

DISCONNECT

SWITCH

CME1202 & CME1402

January 1995

Page 7