INITIAL START UP
12. After an ice harvest check Cube Size.
There is just enough water available in the
reservoir to make one full sized batch of cubes.
The water pump may pick up some air at the end
of the freezing cycle, so at the end of freeze some
bubbles in the pump discharge hose is normal. If
the water pump stops pumping water before the
end of freeze, the cube size control may be set too
cold, or the water system may be leaking water.
Compare cube size to the "Cube Size Diagram"
To adjust cube size, locate cube size control on the
front of the control box. Rotate the adjustment
screw one eighth of a turn:
••
Clockwise for LARGER ice cubes
••
COUNTER Clockwise for SMALLER ice cubes
Observe size of the ice in the next ice cube
harvest and repeat the adjustment until the correct
ice cube size is achieved.
JUST RIGHT
TOO SMALL
When the cubes are the correct size, they will be
connected together vertically, and drop off in strips.
The batch weight will be about 13.5 to 14.5 lb.
Note: If the cubes at the bottom rows of some
evaporators are smaller than others, the size difference
does not affect capacity or performance. However, there
should be some ice in all cells. If not, contact the Factory.
CUBE SIZE DIAGRAM
CME1202 & CME1402
May 1995