HID312AW, HID525AW and HID540AW

Installation and User’s Manual

March 2015

Page 8

Installation

Installation should be done by an experienced ice

machine installer. To locate one, call the number on

the back of this manual or go to Scotsman’s website

www.scotsman-ice.com to identify a local distributor or

service company.
The machine will require power, water and drain.

Locate the water supply fitting on the lower back of

the cabinet and obtain the correct fitting to connect

the water supply.
Plumbing Fittings:

• Potable water inlet: 3/8 male flare.
• Cabinet drain: 3/4 FPT.

All models:
Note: Wall mounting limits access to the utility

connections which are at the back bottom of

the machine. Pre-plumbing the water and drain

is required so that stubs are available for final

connection to water and drain.
Connect the potable water supply tube to the 3/8

inch male flare inlet at the bottom back of the unit.

Water filters may be used but are not required. Note

that activated carbon or charcoal water filters are

used for taste and odor problems but also take out

any chlorine that the local water agency may have

added for purification. That can require more frequent

sanitization of the equipment.

Connect drain tubing to the 3/4 inch FPT central drain

fitting at the back of the cabinet. Use 3/4 inch rigid

tubing, use material to meet local codes. The drain

basin in the machine will act as an internal vent, no

additional vent should be required unless there is a

very long horizontal run. Drain tubing must pitch down

1/4 inch per foot to the building drain. Insulation of

drain tubing is recommended for most environments.

Install Wall Mounting Brackets
See next page for detailed instructions.
Electrical Supply - 115 volt models
Plug the unit into a dedicated 15 amp outlet. The unit

must be the only device on the circuit. Confirm the

outlet is properly grounded and is in good condition.

Worn outlets should be replaced as they can cause

erratic operation of equipment. Do not use an

extension cord. Do not cut off the ground plug on the

power cord.
Ground fault outlets are not recommended. If ground

fault is required a ground fault breaker should be

used.
Use the services of a licensed electrician when

needed and conform to local and national codes.
Position the unit in its final location.
Level the unit front to back and left to right.

Drain Tubing

Potable Water

Connection