Page 10
Plumbing Requirements
All models require connection to cold, potable water.
A hand actuated valve within site of the machine is
required. Air cooled models have a single 3/8” FPT
inlet water connection.
Water cooled models have a 1/2" FPT drain fitting
plus an additional 3/8” FPT condenser inlet water
connection.
Water Filters
If connecting to water filtration, filter only the water
to the reservoir, not to the condenser. Install new
cartridges if the filters were used with a prior machine.
A triple head filter is recommended. Either the
Scotsman SSM3 taste and odor filter system, or the
ADS-AP3 Aqua Patrol system.
Water Fitting
Field Supplied
Inlet Water Connection