Research Concepts RC1500 User Manual
Page 19
Antenna Setup
19 RC1500B Quick Start Guide
Power up the RC1500.
Activate the LIMITS mode by first locating the following screen. Hit ENTER to proceed
past the prompt message.
POS SS
ENTER TO PROCEED
MODE TO EXIT LIM
MODE
Next you will be prompted with the following display.
POS SS
174 210
7 – SET Down LIM
MODE
Use the UP and DOWN keys to position the actuator. Hit the 7 key to set the Down
Limit.
Up Limit
10. In this step the ACU Up limit is set. Motor the antenna up until the position reading
is 260. Hit the 7 key to set the up limit. Once the up limit is set, the controller should
move to the CONFIG mode.
Slow Speed
The slow speed in the CONFIG mode can be adjusted to aid in initially locating the
satellite. It is best to set the slow speed to the value shown below.
POS SS
SLOW SPEED: 135
0 – 254
CFG
MODE