Remotec ZTS-110 V3.05 User Manual
Page 9

15
16
Note: Explanations of Swing and Differential set point
HEAT mode: thermostat controls the temperature according to the following
diagram
o o
o
Example for Heating: (Set point = 70 F, Swing = 1 F, Differential = 2 F)
o o
=> 1st stage heater turns on when room temp is 69 F and off at 71 F.
o o
=> 2nd stage heater turns on when room temp is 67 F and off at 70 F.
LCD indication
Step
Procedure / Description
Press "Prog" key once to confirm the setting
and it will go to Advanced Recovery setting.
Press Up/Down key to enable/disable
Advanced Recovery Mode.
9
Press "Prog" key once to confirm the setting
and it will go to the Home page.
10
RECOVERY
RECOVERY
WAKE
AM
MO
FAN AUTO
PROG ON
OFF
Diff
Swing
SD= switch differential
Swing
Temperature
Output
Off
Heat
st
1 Turn off
nd
2 Turn off
Set point
st
1 Turn on
nd
2 Turn on
COOL Mode: thermostat controls the temperature according to the following
diagram
o o
Example for Cooling: (Set point = 80 F, Swing = 1 F)
o o
=> Cooler turns on when room temp is 81 F and off at 79 F.
AUTO:
thermostat controls the temperature according to the following
diagram
o o
There is a dead band 4 F/2 C between heat set point and cool set point.
o
Example 1: If user select heat set point is 70 F, the minimum cool set point will be
o o
limited at "heat set point" + 4 F: 74 F
o o
Pervious heat set point is 70 F and cool set point is 74 F
o
Example 2: If user changes heat set point to 72 F, cool set point will be updated to
o
76 F automatically to maintain the dead band.
Swing
Temperature
Output
Off
Cool
Turn off
Set point
Turn on
Temperature
Output
Off
Heat
st
1 Turn off
nd
2 Turn off
Heat Set point
st
1 Turn on
nd
2 Turn on
Diff
Swing
Swing
Dead band
Cool Set point