Battery Low Indication
Defrost Indication
Out of Temperature Range Indication
23
24
LCD indication
Procedure / Description
ZTS-110 thermostat will detect the battery
level every 30 minutes; Battery low icon will
be displayed at Home page if the battery is
running out. (User is required to change new
batteries.)
WAKE
AM
PROG ON
MO
HEAT
PUMP
LCD indication
Procedure / Description
DEFROST icon will be displayed at Home
o
o
page if temperature below 41 F/5 C.
All heaters will be forced On, except in cool
mode.
WAKE
DEFROST
AM
TU
HEAT
FAN AUTO
1
2
PUMP
Advanced Recovery Indication
LCD indication
Procedure / Description
The Advanced Recovery feature allows
heating and cooling systems to gradually
recover from an energy-saving set point
t e m p e r a t u r e t o a c o m f o r t s e t p o i n t
temperature. Advanced Recovery calculates
the time needed to adjust the temperature to
the next program setting. When the thermostat is in
Advanced Recovery mode, the display will show
"RECOVERY".
Advanced Recovery is an option that allows
the HVAC system to attempt to recover from
a s e t b a c k p e r i o d a n d r e a c h a d e s i r e d
c o m f o r t t e m p e r a t u r e s e t p o i n t b y t h e
b e g i n n i n g o f y o u r p r o g r a m m e d c o m f o r t
p e r i o d . T h i s o p t i o n a l l o w s t h e c h o i c e
whether to use Advanced Recovery under
Setting Mode.
(Recovery works in heat, cool and auto
mode. Maximum Advanced Recovery time
is one hour.)
WAKE
AM
MO
HEAT
FAN AUTO
1
RECOVERY
LCD indication
Step
Procedure / Description
HI icon will be displayed on LCD if
temperature excess the measurement
o o
ranges 99 F/40 C.
All heaters will be forced Off.
Cooler will turn on if running cool mode.
1
WAKE
AM
TU
FAN AUTO
1
COOL
WAKE
DEFROST
AM
TU
HEAT
FAN AUTO
1
2
PUMP
LO icon will be displayed on LCD if
temperature below the measurement ranges
o o
32 F/0 C.
All heaters will be forced On, except in cool
mode.
2