Remotec ZTS-110 V3.05 User Manual
Page 16

Note:
- It is recommended to perform the Delete/Exclude procedure before doing
Add/Include. This is to make sure the ZTS-110 is not in any other Z-Wave
network which will result in failure in Inclusion process.
- If the inclusion is failed, try exclusion, and/or reset ZTS-110 to factory default and
try inclusion again.
- After ZTS-110 is included to Z-Wave network, it will stay in Easy mode by default.
- You can enable or disable Easy mode by local "Setting Mode" or Z-Wave
parameter number 8.
(please refer to parameter table at Z-Wave Configuration Parameters).
29
30
LCD indication
Step
Procedure / Description
Gateway / Controller device should be set
to inclusion mode.
Press and hold "Home" key for 2 seconds
to set ZTS-110 to Add (Inclusion) / Delete
(Exclusion) Mode.
1
Press "Prog" key once, it will search the
network.
2
If the ZTS-110 is added into the network
successfully, the signal of "done" will
appear.
3
Press "Home" key once to go back to the
home page.
will appear on the main display.
4
WAKE
AM
PROG ON
MO
COOL
FAN AUTO
Delete (Exclude) ZTS-110 from Gateway / Controller Z-Wave
network
Support Association Groups (Association Command Class)
ZTS-110 supports 3 association groups.
LCD indication
Step
Procedure / Description
Gateway / Controller device should be set to
Exclusion mode.
Press and hold "Home" key for 2 seconds
to set ZTS-110 to Add (Inclusion) / Delete
(Exclusion) Mode.
1
Press "Prog" key once, it will search the
network.
2
If the ZTS-110 is removed from the network,
it shows no connection. Exclusion is
completed.
3
Press "Home" key once to go back to the
home page.
will appear on the main display.
4
WAKE
AM
PROG ON
MO
FAN AUTO
OFF
Association group
Association group_1
(Heat pump)
Association group_2
(Compressor)
Mode
Heating mode
ON
(basic set command 0xFF)
OFF
(basic set command 0x00)
Cooling mode
OFF
OFF
(basic set command 0x00)
OFF
(basic set command 0x00)
ON
(basic set command 0xFF)
OFF
(basic set command 0x00)