Remko fresh water station – REMKO EFS 35 User Manual
Page 8

Flow meter technical data
Series
FlowSonic
Dimensions
Height
mm
125
Top connection
Inch
1" IG (DN20)
Bottom connection
Inch
1" IG (DN20)
Hydraulic
Measurement range
l/min
1-100
Maximum permitted temperature
°C
100 (Medium)
Maximum permitted pressure
bar
16 (pressure impulses max. 25 bar)
Usable medium
Water (suitable for drinking water)
Kvs-value
8
Flow metering
Accuracy
± 10% (of the measurement value)
Reaction time
sec.
< 1
Equipment
Medium flow rate probe
Ultrasonic probes
Electrical data
Supply voltage
V
5 V DC
Output signal
U
out =
0,03153 * V [l/min] + 0,35 V
V
l
min
( )
Power consumption
mW
< 100
Protection class
IP
44
Conductor colours
White
Flow rate (V)
Green
GND
Brown
Supply voltage (+ 5 V)
Environment
Ambient temperature
°C
0-70
Air humidity
% rel.
0-95 (relative), non-condensing
REMKO fresh water station
8