Remko fresh water station – REMKO EFS 35 User Manual
Page 20

Temperature in
buffer tank probe
S08
[°C]
HW temperature
set on the con-
troller
[°C]
Maximum medium
flow rate from the
fresh water sta-
tion with the set
HW temperature
[l/min]
Maximum dis-
pensing medium
flow rate at the
water valve for an
HW Temperature
of 45 °C
[l/min]
Transmission
capacity of the
fresh water sta-
tion
[kW]
55
45
57
141
60
37
53
129
75
40
65
---
135
45
65
---
158
50
60
68
166
55
51
65
159
60
43
61
151
80
40
65
---
135
45
65
---
158
50
65
74
181
55
57
72
176
60
49
69
169
Reheating is not considered if the cold water tem-
perature is 10 °C
* maximum medium flow rate: 25 l/min, pressure
loss of the fresh water station is 1000 mbar in this
case (higher values are possible in a limited way
hydraulically).
REMKO fresh water station
20