Fig. 4: Distance between the holes
8.
Hang the fresh water module onto the
screws. Tighten the screws so that the insu-
lation on the sides is flush to the wall.
9.
Connect the pipes of the fresh water module
to the system in accordance with Fig. 5.
1. Primary side:
Return flow to buffer tank,
Connection 1/2" OT,
Piping at least DN 25, 28 x 1,5 mm,
Maximum length 2 m
2. Secondary side:
Hot water circulation, return,
Connection 1" OT, flat-sealing
3. Secondary side:
Cold water inlet,
Connection 1" OT, flat-sealing
4. Secondary side:
Hot water outlet,
Connection 1" OT, flat-sealing
5. Primary side:
Inlet from buffer tank,
Connection 1 1/2 OT,
Piping at least DN 25, 28 x 1,5 mm,
Maximum length 2 m
A
B
1
2
3
5
4
Fig. 5: Piping of the fresh water station
A: Pipe distance from the wall
(secondary) = 167 mm
B: Pipe distance from the wall (primary) = 95 mm