3
Unit description
The fresh water station is a pre-installed valve
group that was checked for leak tightness; it is
used to transfer heat between the buffer tank and
the domestic water circuit. It contains a pre-set
controller and important valves for operating the
system:
n
Ball valves in the primary circuit
n
Piston valves in the secondary circuit
n
Safety valve in the secondary circuit
n
Pre-installed controller
n
Temperature probe on the cold water supply
n
Temperature probe on the heating supply
n
Ultrasonic flow rate meter on the domestic hot
water outlet
n
Primary pump that can be shut off
n
Ball valve for filling/drainage, for bleeding the
heat exchanger and the pump
NOTICE!
A check for pressure and leak tightness after
successful installation must always be per-
formed before commissioning
A
B
C
D
1
2
3
4
7
6
8
9
10
11
5
Fig. 2: Product description
A: Secondary side: Hot water outlet
B: Primary side: Inlet from the buffer tank
C: Primary side: Return flow to the buffer tank
D: Secondary side: Cold water inlet
1:
Piston valve (hot water outlet)
2:
Fill/drain valve
3:
Safety valve, 10 bar
4:
Temperature probe, fast
5:
Primary pump
6:
Ball valve
7:
Ball valve with gravity brake
8:
Analogue medium flow rate temperature probe
VFS 2-40
9:
Heat exchanger
10: Temperature probe, fast
11: Piston valve (cold water inlet)
9