Unit description

The fresh water station is a pre-installed valve

group that was checked for leak tightness; it is

used to transfer heat between the buffer tank and

the domestic water circuit. It contains a pre-set

controller and important valves for operating the

system:

n

Ball valves in the primary circuit

n

Piston valves in the secondary circuit

n

Safety valve in the secondary circuit

n

Pre-installed controller

n

Temperature probe on the cold water supply

n

Temperature probe on the heating supply

n

Ultrasonic flow rate meter on the domestic hot

water outlet

n

Primary pump that can be shut off

n

Ball valve for filling/drainage, for bleeding the

heat exchanger and the pump

NOTICE!

A check for pressure and leak tightness after

successful installation must always be per-

formed before commissioning

A

B

C

D

1

2

3

4

7

6

8

9

10

11

5

Fig. 2: Product description

A: Secondary side: Hot water outlet

B: Primary side: Inlet from the buffer tank

C: Primary side: Return flow to the buffer tank

D: Secondary side: Cold water inlet

1:

Piston valve (hot water outlet)

2:

Fill/drain valve

3:

Safety valve, 10 bar

4:

Temperature probe, fast

5:

Primary pump

6:

Ball valve

7:

Ball valve with gravity brake

8:

Analogue medium flow rate temperature probe

VFS 2-40

9:

Heat exchanger

10: Temperature probe, fast

11: Piston valve (cold water inlet)

9