2 design of the storage tank, Design of the storage tank – REMKO EFS 25 User Manual
Page 11
4.2
Design of the storage tank
You can use the following table to calculate the approximate required volume of the buffer tank.
Temperature in buffer tank [°C]
HW temperature [°C]
set in controller
Reqd. Storage tank volume per
litre of HW [Litre]
50
45
1.5
60
45
0.9
50
1.2
55
1.6
70
45
0.7
50
0.9
55
1.0
80
45
0.6
50
0.7
55
0.8
Sample calculation for the design of the buffer tank:
Temperature of buffer tank: 60 °C, required dispensing medium flow rate at water valve: 20 l/min
DHW temperature set on the controller: 45 °C
How large must the Storage tank be if a 20-minute dispensing operation is to take place without reheating?
20 l/min x 20 min = 400 l
400 l x 0,9 = 360 l ð The heated part of the buffer tank must be 360 litres in size.
The hot water volume depends on the position of the installed S 08 probe (Smart Control hot water
probe). The higher this is installed on the buffer tank, the lower the hot water volume.
11