The storage tank is not suitable for
preparing drinking water!
!
CAUTION
Installation may only be performed
by authorised specialists.
Preparation of the hot water must
be in compliance with the latest
applicable standards.
NOTE
Installation
General Information
■
Do not continually top up the water
level in the storage tank. This will
avoid corrosion damage to the tank.
■
If aggressive water is an issue, please
note that special models of the tank
can be tested (address all queries to
your contractual partner)
■
In hard water areas, connect
a standard descaling device upstream
of the tank.
■
It is essential to bleed the storage
tank.
■
When planning the unit's installation
surface and selecting the installation
location, note the total weight of the
storage tank, including the weight
of the water (the nominal capacity),
in order to ensure that the statics
of the load-bearing surface are not
exceeded.
■
Ensure proper clearance from firing
systems.
■
Make sure that units with enclosures,
which are installed in small, tight
spaces or in suspended ceilings
have the connection block (water
and electric connections and heater
installation) still freely accessible and
that there us no buildup of heat.
■
Leave at least 500mm of space
free for the removal of the heating
flange.
■
Check the contents of the packaging
for completeness and check the
unit for visible transport damage.
Immediately notify your contractual
partner of any deficiencies.
■
The unit must be assembled on site.
■
For all connecting sockets, ensure
that the thread is fully engaged.