beautypg.com

Remko, Decommissioning, Description – REMKO HPS500 User Manual

Page 6

background image

6

REMKO

HPS 500, MPS 800, MPS 1000

Decommissioning

Temporary shutdown

1. Disconnect the electrical connection

at all poles.


2. Drain the tank in areas where it is at

risk from frost and before the

onset of winter.


3. Then also drain all cold water pipes

leading to the heating elements

and to the unit itself as well as all

water-carrying valves, fittings

and lines (even the heating circuit

= register) back as far as the frost-

proof section of the domestic water

system (domestic water connection).

!

ATTENTION

When emptying the tank, hot

water may escape!

!

ATTENTION

When placing the tank back into

service, ensure that it is filled with

water and that water which is free

of bubbles is escaping from the

valves!

Permanent decommissioning

Ensure that equipment and components

are disposed of in accordance with local

regulations, e.g. through authorised

disposal and recycling specialists or at

collection points.

REMKO GmbH & Co. KG or your

contractual partner will be pleased to

provide a list of certified firms near you.

Description

The storage tanks are employed for
the storage of hot water in all types of
warm water central heating systems
(solid fuel/oil-fired boilers, heat pumps,
solar energy systems, gas/electric
instantaneous water heaters) within
enclosed spaces and for the storage of
cold water for cooling processes or heat
recovery purposes.

The tank volume can be adapted to
your particular needs by connecting
several storage tanks to form batteries.
The storage tanks may be used
universally, either as parallel storage
(hydraulic switch) or series storage.

The insulation of the HPS 500 and
MPS 800/1000 hot water tanks consists of
a 100 mm thick layer of silver-grey flexible
foam.

All storage tanks are produced from
high-quality steel acc. to DIN EN
10025/10111, and are provided with an
anti-rust coating on the outside.
Immersion heater elements can be
screwed into the in-built 6/4" socket in
the storage tanks.
For retrofitting a fin-tube heat
exchanger a D240 blank flange cover is
included.
The storage tanks have 9 (11 for the
MPS 1000) 6/4" IG connection threads
as well as inflow restrictors.
To enable to use of sensor/thermometer
immersion sleeves, the unit incorporates
four 1/2" socket screw threads.

This manual is related to the following products: