Remko, Kps 300, Installation – REMKO KPS300 User Manual
Page 8

8
REMKO
KPS 300
■
Check the contents of the packaging
for completeness and check the
unit for visible transport damage.
Immediately notify your contractual
partner of any deficiencies.
■
The unit must be assembled on site.
■
For all connection ports, ensure that
the thread is fully engaged.
The storage tank is not suitable for
preparing drinking water!
■
Ensure that the area in which
the unit is to be operated is free
of frost and easily accessible for
required maintenance, repairs and
even for the possible replacement
of the unit (e.g. avoid overly narrow
thoroughfares and doorways).
■
When installing the storage tank
in unusual locations, such as in lofts,
residential units with floors that
are sensitive to water, storerooms,
etc. take account of the possibility
of leaking water, and ensure that a
facility is in place to catch the water,
including appropriate drainage
methods.
■
The unit may only be positioned and
operated on level surfaces.
■
When planning the unit's installation
surface and selecting the installation
location, note the total weight of the
storage tank, including the weight
of the water (the nominal capacity),
in order to ensure that the statics
of the load-bearing surface are not
exceeded.
■
Ensure proper clearance from firing
systems.
■
Make sure that units with enclosures,
which are installed in small, tight
spaces or in suspended ceilings
have the connection block (water
and electric connections and heater
installation) still freely accessible and
that there us no buildup of heat.
■
Leave at least 500mm of space free
for the removal of the cleaning/
heating flange.
Installation
General Information
■
Do not continually top up the water
level in the storage tank. This will
prevent corrosion damage to the
tank.
■
If aggressive water is an issue, please
note that special models of the tank
can be tested (address all queries to
your contractual partner)
Central heating connection
Before being placed into service, the
heat distribution must be rinsed out in
order to remove any soiling (e.g. scale)
from the heating circuit.
Installation
!
ATTENTION