REMKO PG 12 User Manual
Page 8
8
! * (
+
1~
L1
1
2
3
4
1
2
3
4
KL
MV2
M
BS
Z
PZ
TE
MV1
TB
N
PE
! (
Any operation/handling which does not correspond to that indicated in these instructions is prohibited,
otherwise we will not be responsible and the guarantee will become void.
The orderer or the customer must have properly filled out the
“guarantee certificate”
which is enclosed with every
REMKO automatic heater and must have returned it to REMKO GmbH & Co. KG within
a timely acceptable period based on the sale and commissioning, to be entitled to
possible guarantee claims regarding faulty material.
KL – terminal strip
BS = operating switch
MV2 = gas valve 2
M = fan motor
Z = ignition electrode
PZ = piezo igniter
TE = thermocouple
MV1 = gas valve (thermoelectric)
TB = temperature limiter
Series
PG 12
Nominal heat output
kW
12
Heating capacity
kW
12
Air output
m³/h
250
Fuel/type of gas
liquified gas
Cat. I
3B/P
{AT, BE, CH, DE, DK, FR, IT, LU, NL, NO, SE }
Gas pressure
mbar
300
Gas consumption
kg/h
0,95
Electrical connection
V
230
Frequency
Hz
50
Power consumption max.
W
60
Fuse protection
A
10
Kind of protection
IP
44
Sound pressure level L
pA
1m
1)
dB(A)
57
Weight
kg
6,8
Dimensions total
length
mm
400
width
mm
185
height
mm
320
1)
noise measuring DIN 45635-01-Kl3 in heating operation