Depending on the operation conditions the units are to

be tested by an expert when necessary, but at least re-

gularly every two years, to ensure their safe operation.

The test result is to be recorded in a test certificate

which is to be safely kept until the next test so that it

can be presented to the authorized persons for control

purposes at any time.

If any faults are stated the supervisor is to be informed.

If the faults affect the unit’s operational reliability, ope-

ration is to be stopped!

Regular maintenance and care, at least after each

heating period is the basic condition for a long servi-

ce life and a faultless operation of the unit.

Make sure to keep the unit free from dust and other

deposits and to clean it only with a dry or humid cloth

(do not use water jet).

Do not use sharp or solvent-containing cleaning a-

gents.

Check suction and blowing out lattice regularly to

see whether it is dirty and clean it, when necessary.

Check the suction opening for combustion air as well

as the injector fitted behind it and the gas nozzle re-

gularly to make sure that they are not dirty.

Check gas hoses and sealings to see whether they

are damaged and replace when necessary.

Clean gas burner and gas nozzle regularly.

Clean baffle plate regularly.

Check ignition electrode and set when necessary.

Check thermocouple and clean when necessary

The bi-metal spring may neither be damaged nor

bent in or order not to affect the function of the tem-

perature-limiter!

When the unit is being maintained, set or

repaired, the gas supply has to be cut off and

the mains plug has to be unplugged from the

mains socket!

Setting and maintenance work is to be carried

out only by authorized specialists!

Disassembly for Cleaning

1.

Demount 4 fastening

screws (1) and pull off

outside casing to the.

front

2.

Demount 3 fastening

screws (2) of air suction

grille.

3.

Demount air suction grille

with fan motor and fan

blade and pull inner ca-

sing to the front.

Cleaning

After disassemly all components are easily accessible

for cleaning and maintenance purposes.

Clean burner using compressed air.

Clean gas nozzle carefully when necessary.

Carefully remove dirt and dust from ignition electro-

de, thermocouple and temperature limiter.

Remove deposits and other dirt from base of device.

Assemble all the parts thoroughly in reverse order.

Control the functions of the complete unit and

carry out a tightness check for all gas-bearing

connections using soap solution and leakage de-

tection spray, respectively.

ignition

electrode

thermo-

couple

3 mm

temperature

limiter

gasburner

Intensive yellowish flames indicate that the fresh

air supply is probably insufficient and that there is

some dirt inside the unit, respectively.

2

1