When using this unit make sure always to observe the

applicable building and fire protection regulations as

well as the rules of the trade cooperative association.

The unit may be operated only by those persons who

have been instructed accordingly.

The unit is to be installed and operated in such a

way as to ensure that the employees are not endan-

gered by waste gases and radiation heat and that no

fire can break out.

The unit may only be installed and operated in

rooms, when the air rate fed to the unit is sufficient

for combustion.

Make sure to install mobile liquid gas reservoir on a

solid ground and in a vertical position.

Liquid gas reservoir may never be used in a lying po-

sition while the unit is operating (gas leakage in the

liquid phase).

The unit may be operated only in well aerated

rooms. Persons may not stay permanently in the

room where the unit has been installed. Relevant

prohibition signs are to be fastened to the entrances.

The unit is to be installed and operated on a solid

non combustible ground.

It is to be ensured that no combustible objects/

materials can be sucked in.

The unit may not be installed or operated in inflam-

mable and explosive surroundings.

A safety zone of 1.5 m around the unit and a mini-

mum distance of 3 m at the unit’s exhaust opening a-

re to be observed, even regarding non combustible

objects.

The unit’s exhaust opening may not be reduced or e-

quipped with hoses or pipings.

Make sure not to introduce foreign matters into the u-

nit.

The air suction lattice is always to be kept free from

dirt and loose objects.

Make sure not to expose the unit to direct water jets.

All electric cables outside the unit are to be protected

from damage (e.g. caused by animals, etc.).

Make sure to cut off the gas supply and to pull the

mains plug out of the mains socket when maintenan-

ce and repairs are carried out.

Safety devices may be neither overbridged nor

blocked.

!

The unit may be operated only by those persons who

have been instructed regarding the unit’s operation

and the handling of liquid gas.

When using the unit make sure always to obser-

ve the guiding principles of the countries and

states concerned.

The unit may only be operated in rooms when

– the air rate fed to the unit is sufficient for com-

bustion and

– the rooms are well ventilated and deventilated

and

– the percentage of the substances which are

injurious to health in the breathed in air has

no inadmissible concentration.

A

good and natural ventilation and deventilation

is given if e.g. the room volume in m³ corresponds to

at least 30 times the nominal heat load in kW of all

the units being operated in the room, and if a natural

air exchange through doors and windows is ensured,

or

if there are permanently open ventilation possibili-

ties for ingoing and outgoing air near the ceiling and

the floor, of which the size in m² corresponds to at le-

ast 0.003 times the nominal heat load in kW of all the

units being operated in the room.

A uniform unit connection pressure of 0.3 bar (300

mbar) of category

I

3B/P

is necessary for all countries

of the European Community.

The connection pressure may not fall below or

exceed the required value.

Make sure to use exclusively components, such as

gas hose, pressure controller and hose security devi-

ces (protection against breakage) or safety devices

against gas leakage, that have been tested and are

suitable for the intended purpose. The pressure cont-

rollers must have a firmly regulated initial pressure of

300 mbar and are to be equipped with a security de-

vice against hose breakage.

Hose pipes are to be protected generally against

chemical, thermal and mechanical damage.

The persons charged with the operation of the unit

have to check it prior to starting work to make sure

that there are no visible defects. If there are defects

which affect the unit’s operational reliability, its ope-

ration is to be stopped!

The unit may be only maintained by trained persons

and only original spare parts may be used.

If the unit has been switched off by the temperature

limiter due to overheating, the reason for the fault

has to be detected and eliminated.

This manual is related to the following products: