beautypg.com

REMKO PG 12 User Manual

Page 5

background image

5

Open bottle valve(s).

When gas is taken out of several

gas bottles simultaneously, all

the valves have to be opened.

Press release button of the hose

security device (protection a-

gainst breakage)

after having o-

pened

the valve(s).

This has also to be done after

each replacement of bottles.

After the installation and

connection of the units all

the gas bearing connecti-

ons have to be checked

with soap solution, leakage

detecting spray etc. to

make sure that they are

tight.

Do not use open flames!

Hint!

Insufficiently dimensioned supply plants can cause i-

cing of the pressure gas or pressure reservoirs. When

the gas pressure falls a proper gas supply to the consu-

mer points can no longer be ensured in many cases.

This will result in imperfect combustion, harmful waste

gases or extinction of the flame. Therefore the supply

plant is to be dimensioned in such a way as to ensure

that problems of this kind cannot be caused.

The cristalline white frost may not be removed by open

fire, glowing objects or radiators. Sufficient gas supply

to the consumer points can be ensured by using an e-

vaporator.

Sufficient gas supply is to be ensured according to the

unit power rating (see identification plate), service life

and ambient temperature of the supply tanks.

In principle, we recommend that you use a set of at le-

ast 3 cylinders to avoid intensive icing of the reservoirs.

The number of cylinders can be increased by using a

set of several cylinders (accessories), depending on

the unit capacity and the service life.

1) Unscrew gas hose

Turn union nut clockwise

Important Installation Hint

When installing or removing the gas hose make sure to

exert a counterpressure

on the

gas connection

nipple

of the unit using an open-end spanner SW 19

and observing the left-handed thread.

This procedure also refers to all further gas compo-

nents, such as pressure controller, hose security device

(protection against breakage), etc.

When any work is carried out on the gas supply

line and when the gas cylinder is replaced, all

stop valves must be closed and there may be

no ignition sources in the direct surroundings.

2) Fasten gas hose

Turn union nut anti-clockwise

#

Make sure to charge a person with the operation of the

unit and with the supervision of the reservoirs and of

the bottle stock who has been instructed sufficiently re-

garding the handlings concerned.

The persons charged with the operation of the units ha-

ve to check the units before starting work to detect ob-

vious defects on the operating and safety elements and

to make sure that the safety devices have not been re-

moved.

Make sure to draw the operators‘ attention to possible

dangers during the handling of liquid gas.

A constant unit connection pressure of

0.3 bar (300 mbar) must be ensured, also

during continuous operation.

Connect pressure controller to

the gas bottle(s).

Attention!

left-handed thread!

Install only in well ventilated rooms, not in rooms which people will be using for longer periods!

This manual is related to the following products: