Press down pin (2) of thermoelectric

gas valve (safety pilot).

Put the operating switch into po-

sition "O"(= Off) and plug the

mains into an appropriate mains

socket with

fault current safety

switch

(230V/1~ 50 Hz).

Close all the bottle valves.

Let flame burn out.

The fan should still run for a few

seconds to exhaust the accumu-

lated heat.

Put operating switch (1) into “0”

position (= off) and unplug mains

plug from the mains socket.

'

# % ( )

Important Hints!

Make sure that the supply air can be freely sucked

and the heated air can be blown off without prob-

lems.

The suction and blower apertures of the unit may

not be narrowed or equipped with hoses or condu-

its.

Make sure to keep the safety distance from com-

bustible and inflammable materials and to observe

the local fire protection codes.

After approx. 2 or 3 sec. the piezo

igniter (3) is to be actuated (possibly

several times) with the pin (2) still

held down, until a formation of flames

has occured.

Put the operating switch into "I"

position (= heating operation)

The supply air fan starts.

After the formation of flames still hold down the pin (2)

for approx. 10 - 15 seconds, until the thermoelectric

flame monitoring has started.

Do not release the pin before this.

If the flame is extinguished after the pin has been re-

leased, repeat the ignition procedure after having wai-

ted for approx. 1 minute. Then keep the pin pressed

down a little longer.

Important!

Make sure to place gas reservoir only laterally behind

the unit! Never heat up or defrost gas reservoir through

the unit’s hot air current (

danger of explosion!

).

Never use gas reservoir in a lying position when the u-

nit is operating (gas leakage in the liquid phase).

Assembly of Multi-bottle Set

To avoid intensive icing of the gas bottle during a lon-

ger operation of the unit, we recommend that you use a

bottle battery consisting of at least 3 bottles. All bottle

valves must be open to ensure regular gas supply!

The electric connection of the unit is to be carried

out according to the VDE 0100 regulations

§ 55, via a special supply point with fault current

safety switch.

2

3

1

1

1

T-connection

high pressure hose 0.4 m

pressure controller

hose-break protection

gas hose to unit