beautypg.com

Shutting down the unit – REMKO RWK 260 User Manual

Page 9

background image

9

Manual operation

The unit can be manually operated, if, for example, the
infrared remote control is not functioning properly or
has been lost.

Open the air inlet grille of the indoor unit and press the
button on the right side.
The following operating modes are then activated:

MODE =

Automatic

(Operating cycle of the compressor

On

→ 20 min. Off → 10 min.)

TEMP. =

24

°C, FAN = Automatic,

SWING =

On,

TIMER

= Off.

Shutting Down the Unit


Temporary shutdown

1. Let the unit run in cooling mode for 30 minutes at a

temperature setting of 31°C.

2. Switch the indoor unit off using the remote control.
3. Disconnect the system with the main switch or fuse

protection from the power supply.

4. Check the indoor unit for visible damage.
5. Clean the indoor unit as described in the

“Maintenance and Service” section.

Permanent shutdown

For environmental safety reasons, the air conditioners
may only be disassembled by authorised service cen-
tres.
REMKO GmbH & Co. KG or your contract partner would
be happy to provide you with the name of a dealer in
your area.

Manual air distribution
There are individually adjustable air directing plate fins
on the air outlet side for horizontally distributing the air.
Set the air directing plate fins in the desired position
with the left and right adjustment lever.

Never adjust the fins when the unit is in auto-
matic swing mode! Do not reach into the unit!
There is a risk of injuring your hand on the fan
motor.

Timer Off

Timer Off

30 Sec.

Programmed
time reached

HR. / MIN.

Unit is off

Timer On and Off

Example:
The control mechanism switches on at 10:20 AM
The unit operates until 5:00 PM.
The control mechanism switches off at 5:00 PM.
The unit is off until 10:20 AM.
The control mechanism switches on at 10:20 AM

Once the unit is programmed, the con-
trol mechanism immediately switches
the unit off. The control mechanism
switches the unit on each day at the
programmed time. When the unit is on,
all settings are visible on the display.
When the unit is off, only the timer
settings are visible.

Unit on

Unit off

LED display on the indoor unit

Left adjustment
lever

Right adjustment
lever

Cause

E3 RUN and TIMER LEDs blink alternately.

Unit switches off after approx. 30 seconds.

Fan motor

E5 TIMER LED blinks.

Room air sensor

E6 RUN LED blinks.

Frost protection
sensor

E9 The LEDs blink alternately for 20 minutes.

Unit switches off after another 20 minutes.

Insufficient refrig-
erant

LED display error code

First, remedy the cause of the problem and then reset
the error code display by switching the unit off and off.

Malfunction display

POWER

On / Off

(red)

PROTECT Compressor protection (green)
RUN Compressor

mode

(green)

TIMER Timer

mode

(yellow)

Display

Room temperature / target temperature

error

code

The display changes to the target temperature display
when the settings are made with the remote control.

This manual is related to the following products: