Shutting down the unit – REMKO RWK 260 User Manual
Page 9
![background image](https://www.manualsdir.com/files/802038/content/doc009.png)
9
Manual operation
The unit can be manually operated, if, for example, the
infrared remote control is not functioning properly or
has been lost.
Open the air inlet grille of the indoor unit and press the
button on the right side.
The following operating modes are then activated:
MODE =
Automatic
(Operating cycle of the compressor
On
→ 20 min. Off → 10 min.)
TEMP. =
24
°C, FAN = Automatic,
SWING =
On,
TIMER
= Off.
Shutting Down the Unit
Temporary shutdown
1. Let the unit run in cooling mode for 30 minutes at a
temperature setting of 31°C.
2. Switch the indoor unit off using the remote control.
3. Disconnect the system with the main switch or fuse
protection from the power supply.
4. Check the indoor unit for visible damage.
5. Clean the indoor unit as described in the
“Maintenance and Service” section.
Permanent shutdown
For environmental safety reasons, the air conditioners
may only be disassembled by authorised service cen-
tres.
REMKO GmbH & Co. KG or your contract partner would
be happy to provide you with the name of a dealer in
your area.
Manual air distribution
There are individually adjustable air directing plate fins
on the air outlet side for horizontally distributing the air.
Set the air directing plate fins in the desired position
with the left and right adjustment lever.
Never adjust the fins when the unit is in auto-
matic swing mode! Do not reach into the unit!
There is a risk of injuring your hand on the fan
motor.
Timer Off
Timer Off
30 Sec.
Programmed
time reached
HR. / MIN.
Unit is off
Timer On and Off
Example:
The control mechanism switches on at 10:20 AM
The unit operates until 5:00 PM.
The control mechanism switches off at 5:00 PM.
The unit is off until 10:20 AM.
The control mechanism switches on at 10:20 AM
Once the unit is programmed, the con-
trol mechanism immediately switches
the unit off. The control mechanism
switches the unit on each day at the
programmed time. When the unit is on,
all settings are visible on the display.
When the unit is off, only the timer
settings are visible.
Unit on
Unit off
LED display on the indoor unit
Left adjustment
lever
Right adjustment
lever
Cause
E3 RUN and TIMER LEDs blink alternately.
Unit switches off after approx. 30 seconds.
Fan motor
E5 TIMER LED blinks.
Room air sensor
E6 RUN LED blinks.
Frost protection
sensor
E9 The LEDs blink alternately for 20 minutes.
Unit switches off after another 20 minutes.
Insufficient refrig-
erant
LED display error code
First, remedy the cause of the problem and then reset
the error code display by switching the unit off and off.
Malfunction display
POWER
On / Off
(red)
PROTECT Compressor protection (green)
RUN Compressor
mode
(green)
TIMER Timer
mode
(yellow)
Display
Room temperature / target temperature
error
code
The display changes to the target temperature display