Please observe the following:
We recommend that the customer install a main or
repair switch close to the outdoor unit.
Power is supplied to the indoor unit via a control line
from the outdoor unit.
The system’s fuse protection must comply with the
technical data.
The electrical terminals of the connections are lo-
cated on the lower right hand side of the indoor unit.
Condensation Connection
Condensation forms on the plate fin exchanger of the
indoor unit during cooling operation because tempera-
tures below the dew point are reached.
The indoor unit is equipped with a collection tray and a
condensation hose for the condensation that accumu-
lates.
Follow the instructions below to lay the condensation
hose:
The condensation drainage pipe is generally placed
in the same guideway as the refrigerant pipes.
If, as a result of structural design conditions, it is neces-
sary to have a different guideway for the condensation
hose, the hose can also be guided to the indoor unit
through a different drain.
If the unit is being operated at outside temperatures be-
low 0°C, the pipes must be placed in such a way that
they are protected from frost.
Always use suitable hose clips.
If the condensation is being guided to a drainage
pipe, please install a siphon-like hose guideway.
which acts as an odour seal.
Outdoor unit
Reversing valve
Power supply
Indoor unit
L
N
7
L1
N
L
N
7
8 8
Control conductor
230 V~,
50 Hz,
L1 / N / PE
Fan motor
9
9
PE PE
PE
Connection of outdoor units RKS 526 H to 568 H
Cooling and heating mode
Wiring Diagram
Terminal
Cover
Strain relief
Control line
Control line
Connection of outdoor units RKM 610 to 813
Cooling mode
Outdoor unit
Compressor contactor
Power supply
Indoor unit
A
N
2
L1
N
L
N
PE PE
PE
Control conductor
neutral conductor
phase conductor
230 V~,
50 Hz,
L1 / N / PE
Connection of outdoor units RKS 526 to 568
Cooling mode
Outdoor unit
Compressor contactor
Protecting earthing
conductor
Power supply
Indoor unit
L
N
7
L1
N
L
N
PE PE
PE
Control conductor
neutral conductor
phase conductor
230 V~,
50 Hz,
L1 / N / PE
To connect the units, proceed as follows:
1. Open the air inlet grille.
2. Using a Phillips screwdriver, loosen the cover on the
right side.
3. Connect the unit to the current-free line from the
outer unit.
See Wiring Diagram.
4. Reassemble the unit.
2% incline
Make sure there is an adequate
incline for drainage.
It must be at least 2 %!
The supplied condensation
hose can be extended using
standard hoses.
Since condensation is created, the condensation
pipe must be isolated.
After the hose has been laid, check to make sure
that condensation can drain freely.
Protecting earthing
conductor
Compressor contactor
Protecting earthing
conductor
neutral conductor
phase conductor