10
Regular care and the observation of a number of basic
rules will ensure the units’ long service life and reliable
operation.
Keep the units free of dirt and other deposits.
Clean the units with a damp cloth..
Do not expose the units to a direct stream of water.
Do not use an abrasive cleaning agent or one that
contains solvent.
If the units are extremely dirty, only use suitable clean-
ing materials.
Before and after the operating season, check
whether the diameter of the condensation pipes has
become smaller as a result of dirt.
If so, they must be cleaned.
Clean the air filters of the indoor unit at regular inter-
vals, more often if necessary, as described on this
page.
Cleaning the filters
Clean both air intake filters at intervals of no longer than
two weeks. If the air is extremely dirty, shorten this time-
frame accordingly.
To clean the air filters, proceed as follows:
1. Open the front of the unit by pushing the grille up
and locking it into place.
2. Lift the filters up and then pull them out.
3. Clean the filters using a standard vacuum cleaner.
3. Extreme dirt can be carefully removed with luke-
warm water.
Then let the filters air dry.
4. Replace the filters and close the grille.
Maintenance and Service
Never operate the indoor unit without the air filter.
The air filter prevents the plate fin exchanger of the
indoor unit from becoming dirty and the unit’s per-
formance from being adversely affected.
We recommend concluding a maintenance agree-
ment with a company who specialises in this type of
work.
This will guarantee that the system operates safely
at all times!
Before any work on the units is performed, they
must be disconnected from the power supply and
prevented from being inadvertently switched on!
System Structure
The indoor unit is connected to the outdoor unit with re-
frigerant pipes.
Combinations
RWK 260 RWK 350 RWK 520 RWK 680
RKS 526
RKS 535
RKS 552
RKS 568
RKM 610
RKM 613
RKM 620
RKM 710
RKM 713
RKM 720
RKM 810
RKM 813
Cooling
Cooling and heating
RWH 260 RWH 350 RWH 520 RWH 680
RKS 526H
RKS 535H
RKS 552H
RKS 568H
Outdoor unit
Refrigerant pipes
Outside
Inside
Condenser fan
Shut-off valve
Indoor unit