REMKO RKV 13 C User Manual

Page 6

background image

6

The remote control

1

= Signal transmission display

2

= Operating mode display

3

= Temperature display

4

= Fan operation display

5

= Clock / timer display

6

= Operating mode selection button

7

= On / Off button

8

= Lower temperature button
Clock or Shorten timer program button

9

= Raise temperature button
Clock or Lengthen timer program button

10 = Fan speed selection button
11 = Customisation entry button
12 = Customisation activation button
13 = Air distribution button
14 = Timer ON button
15 = Timer DAILY button
16 = Timer DELETE button
17 = Timer night operation button
18 = Timer OFF button
19 = Clock setting button
20 = Reset button

Yellow light (timer signal)
It lights up if the timer is activated.
It blinks after a power outage, e.g. after the power sup-
ply has been interrupted or if the unit was restarted right
after being switched off in timer mode.

Alarm code

(in 5 second intervals

Description of problem

Blinks 2 times

The float regulator of the conden-
sation tray has been switched off
for longer than approx. 4 min.

Blinks 3 times

The temperature sensor of the fan
is defective or outside of its regu-
lation range.

Blinks 4 times

The frost protection mechanism
has been activated.

Blinks 10 times

EEPROM defective

Green light (ON / OFF signal)
It lights up when the unit is in operation.
It blinks in five second intervals when there is a unit
malfunction.
The blink intervals are an alarm code. Unit operation is
blocked and can only be resumed once the problem has
been fixed and the unit unplugged from the power sup-
ply for a moment.

“Manual emergency operation” sensor

This sensor can be used when the remote control has
been lost or is not working.
After the grating has been opened, a metal protection
plate with the activation opening for the indented sensor
becomes visible.

When the indented sensor is pressed with a suitable
tool for 5 seconds when the unit is shut off, the unit runs
in “manual emergency operation”.
The air-conditioning unit switches on and keeps the
room temperature constant at +22 °C. The fan speed
and air distribution are automatically set. The timer
mode is not activated.
If the infrared sensor receives a signal from the remote
control, the unit operates in accordance with this signal.

= Sensor

20

18

19

15

6

4

5

7

8

11

17

10

13

16

14

12

9

1

2

3

A

AM
PM

A

B

1

2

F