Installation instructions – REMKO RKL 220 User Manual
Page 8
8
Installation Instructions
All units are subject to regular quality controls and are
carefully packaged before being delivery.
It is still important to check your unit carefully to make
sure there is nothing wrong with it before setting it up.
Document any damage on the delivery bill and inform
your delivery company and your contract partner. No
guarantees can be provided for subsequent claims.
Expelling the warm air
During cooling mode, the unit generates warm air. This
air must be expelled from the room being cooled to re-
tain the cooling effect.
Different ways of expelling air
Insert the power plug into a correctly
fused plug socket.
230V/1~ 50 Hz / 10 A fuse.
Make sure that extension cables are
suitable in terms of capacity, length
and intended use.
Keep doors and windows closed
during operation.
In case of direct sunlight, make sure
to close all curtains and blinds.
Make sure that the water tank has
been inserted correctly.
The unit will not start if the tank has
not been inserted or has been im-
properly inserted. When the device
is switched on, the red "FULL TANK"
malfunction light lights up and an
alarm goes off.
Place the exhaust hose in front of the
output opening on the back side of
the unit.
Slide the deflector piece from the top
down into the notches on the side un-
til it clicks into place.
With a fix connection to the exhaust
hose (wall lead-through).
The hose supplied is firmly connected
to a wall lead-through.
Lead-through kits can be purchased
as accessories.
With a flat nozzle.
The flat nozzle supplied can be used
in two different ways.
1. It is possible to guide the flat nozzle
through the open window and se-
cure it firmly using straps and suc-
tion devices.
2. The flat nozzle can also be hung
through the partially opened win-
dow.
To ensure that the unit operates ef-
fectively, place the flexible exhaust
hose at an upwards incline and do not
bend it too sharply.
Place the device securely on a level
and firm surface.
An uneven surface can cause vibra-
tions and disruptive noises.
Ensure that the dust filter has been
properly installed. Never use the unit
without the dust filter installed!
Without a dust filter, the plate fins of
the evaporators become dirty and
performance of the unit suffers.
Recommendations for optimum unit operation.
After unpacking the device, place it
on its transport wheels and let it
stand for a minimum of 5 min. be-
fore switching it on.
5 MIN.
The exhaust hose must always be placed at an up-
wards incline in the direction of the flow of air!
The exhaust hose may not be extended.